The PSt Quick E and F are laboratory equipment designed for the analysis of various substances. They are used for the measurement of partial pressure of oxygen (pO2) and partial pressure of carbon dioxide (pCO2) in samples. The PSt Quick E and F provide accurate and reliable results for these parameters.

Automatically generated - may contain errors

4 protocols using pst quick e and f

1

Gel Permeation Chromatography Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GPC analysis was performed at Toray Research Center (Tokyo, Japan). The purified sample (1 mg) was dissolved in 1 mL of dimethyl formamide (DMF) containing 50 mM lithium chloride (LiCl), and 200 μL of the sample was subjected to GPC. The molecular mass was estimated using a high-performance liquid chromatograph equipped with a refractive index detector (RI-8020; TOSOH, Tokyo, Japan), and TSK gel α-4000 and TSK gel α-2500 columns (7.8 mm × 30 cm; TOSOH, Tokyo, Japan), which were connected directly. DMF containing 50 mM LiCl was used as the solvent at a flow rate of 0.7 mL/min and the column temperature was maintained at 23 °C. The eluted sample was used for molecular mass determination, with a calibration curve obtained using standard polystyrene kits (PSt Quick E and F; TOSOH, Tokyo, Japan).
+ Open protocol
+ Expand
2

Acetylation and GPC Analysis of DHP

Check if the same lab product or an alternative is used in the 5 most similar protocols
The obtained DHP was acetylated with acetic anhydride
and pyridine and analyzed using size exclusion chromatography. The
sample solution was filtered and injected into Shodex GPC packed columns
GPC KF-802 + KF-803L × 2 (30 cm × 8 mm) using a JASCO liquid
chromatography system equipped with a UV/vis detector UV-975 (Tokyo,
Japan). Tetrahydrofuran was used as an eluent with a flow rate of
1.0 mL/min at 40 °C. Polystyrene standards PStQuick E and F (Tosoh,
Tokyo, Japan) were used for molecular mass calibration.
+ Open protocol
+ Expand
3

Gel Permeation Chromatography Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GPC analysis was performed at Toray Research Center (Tokyo, Japan). The puri ed sample (1 mg) was dissolved in 1 mL of dimethyl formamide (DMF) containing 50 mM lithium chloride (LiCl), and 200 μL of the sample was subjected to GPC. The molecular mass was estimated using a high-performance liquid chromatograph equipped with a refractive index detector (RI-8020; TOSOH, Tokyo, Japan), and TSK gel α-4000 and TSK gel α-2500 columns (7.8 mm × 30 cm; TOSOH, Tokyo, Japan), which were connected directly. DMF containing 50 mM LiCl was used as the solvent at a ow rate of 0.7 mL/min and the column temperature was maintained at 23°C. The eluted sample was used for molecular mass determination, with a calibration curve obtained using standard polystyrene kits (PSt Quick E and F; TOSOH, Tokyo, Japan).
+ Open protocol
+ Expand
4

GPC Analysis of Polymer Molecular Mass

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GPC analysis was performed by Torey Research Center (Japan). The puri ed sample (1 mg) was dissolved in 1 mL of dimethyl formamide (DMF) containing 50 mM lithium chloride, and 200 μL of the sample was subjected to GPC. The molecular mass was estimated using a high-performance liquid chromatograph equipped with a refractive index detector (RI-8020; TOSOH, Japan), and TSK gel α-4000 and TSK gel α-2500 columns (7.8 mm × 30 cm; TOSOH), which were connected directly. DMF containing 50 mM lithium chloride was used as the solvent at a ow rate of 0.7 mL/min and the column temperature was maintained at 23°C. The eluted sample was used for molecular mass determination, with a calibration curve obtained using standard polystyrene kits (PSt Quick E and F; TOSOH). 13
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!