The largest database of trusted experimental protocols

Syngo us workplace

Manufactured by Siemens
Sourced in United States

Syngo® US Workplace is a software platform designed for ultrasound imaging applications. It provides a comprehensive suite of tools for image acquisition, review, and analysis. The core function of Syngo® US Workplace is to enable efficient and accurate ultrasound examinations.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using syngo us workplace

1

Cardiac Cycle Imaging and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
To acquire sufficient information, the images were recorded at 60 frames per second. We captured images of a full cardiac cycle through the correlation of two consecutive QRS complexes on an electrocardiogram.
Image analysis was performed using recorded and separately stored raw data. The software used to analyze the data was Siemens Syngo® US Workplace (Siemens Medical Solutions USA, Inc., Malvern, PA, USA).
Through the analysis of data obtained on VVI, we obtained the peak systolic velocity, strain, strain rate (SR), and longitudinal displacement values. The “home view” RV image was divided into six different areas: right ventricular inlet, midinlet, apex-inlet, apex-outlet, midoutlet, and right ventricular outlet. The change in these parameters before and after the procedure was compared (Figure 2).
To minimize inter- and intra- observer variation, images were obtained by a specialist interventionist (J.Y.C.), whereas the images were analyzed by another well-trained pediatric cardiologist (N.K.K) via the manual subendocardial border tracing method, a total of three times. The mean values were recorded for analysis in the present study.
+ Open protocol
+ Expand
2

Carotid Intima-Media Thickness Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ultrasound examination was performed according to the Mannheim carotid intima-media thickness consensus [30] using an 8-MHz annular array ultrasound imaging system (Siemens Acuson P50 Ultrasound system, Software version 2.1; Siemens Medical Solution USA, Inc. Mountain View, California, USA) with integrated digital image evaluation software (Syngo US Workplace, Siemens Medical Solutions, USA Inc., Ann Arbor, Michigan, USA). cIMT was obtained either by five averaged measurements on each side or semiautomatically using a digital image evaluation software. All values were transformed to SDS adjusted for height and sex using reference values established by our group [31] .
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!