The largest database of trusted experimental protocols

H2o lc ms grade

Manufactured by Biosolve
Sourced in United States

H2O (LC-MS grade) is a high-purity water product designed for use in liquid chromatography-mass spectrometry (LC-MS) applications. It is a colorless, odorless, and ultra-pure liquid that meets the stringent requirements for LC-MS analysis.

Automatically generated - may contain errors

2 protocols using h2o lc ms grade

1

Bisphenol A Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
BPA (≥99%), the internal standard (IS) deuterated BPA-d16 (analytical standard), the derivatization reagent pyridine-3-sulfonyl (PS) chloride (≥95%), formic acid (FA, LC-MS grade), methanol (MeOH, LC-MS grade), and acetonitrile (ACN, LC-MS grade) were purchased from Sigma-Aldrich (Saint Louis, MO, USA). H2O (LC-MS grade) was purchased from Biosolve (Valkenswaard, The Netherlands). Dimethylsulfoxide (DMSO), hydrochloric acid (HCl), sodium hydroxide (NaOH), and ammonium fluoride (NH4F) were purchased from Merck KGaA (Darmstadt, Germany). Oasis PRiME HLB (3 mL; 60 mg) extraction cartridges were purchased from Waters Corporation (Milford, MA, USA). AFFINIMIP SPE Bisphenols extraction cartridges were purchased from AFFINISEP (Petit-Couronne, France).
+ Open protocol
+ Expand
2

Bisphenol A Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following chemicals and reagents were used: BPA (≥99%), the internal standard (IS) deuterated BPA-d16 (analytical standard), the derivatization reagent pyridine-3sulfonyl (PS) chloride (≥95%), formic acid (FA, LC-MS grade), methanol (MeOH, LC-MS grade), and acetonitrile (ACN, LC-MS grade) (all from Sigma-Aldrich, Saint Louis, MO, USA), H2O (LC-MS grade, from Biosolve, Valkenswaard, The Netherlands), dimethylsulfoxide (DMSO), hydrochloric acid (HCl), sodium hydroxide (NaOH), and ammonium fluoride (NH4F) (all from Merck KGaA, Darmstadt, Germany). Solid-phase extraction was performed with Oasis PRiME HLB (3 mL; 60 mg; from Waters Corporation, Milford, MA, USA) and AFFINIMIP SPE Bisphenols (from AFFINISEP, Petit-Couronne, France) extraction cartridges.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!