Agilent 6490 qqq

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 6490 QQQ is a triple quadrupole mass spectrometer designed for high-sensitivity, high-throughput quantitative analysis. It features a quadrupole mass filter, a collision cell, and a second quadrupole mass filter for tandem mass spectrometry (MS/MS) capabilities.

Automatically generated - may contain errors

2 protocols using agilent 6490 qqq

1

Mycotoxin Analysis by LC-MS/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC-MS/MS was obtained from Agilent 6490 QQQ (Agilent Technologies, Santa Clara, CA, USA) mass-spectrometer equipped with Agilent 1290 series Rapid Resolution LC system with Agilent Jet-Stream ESI interface (Agilent Technologies, Santa Clara, CA, USA). Mycotoxin separation was achieved on a reversed phase C18 column (ODS) (150 mm × 2.1 mm; 5 µm). Data acquisition, processing, and instrument control were performed through the Mass Hunter Workstation B.06.01 software. MS parameters were optimized by using mycotoxin mixture that contained 100 µg/L AFB1, AFG1, and OTA standards, and 30 µg/L of AFB2 and AFG2 standards in MeOH.
+ Open protocol
+ Expand
2

Quantification of Sulforaphane and Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
In the present study, sample concentrations from in vitro or in vivo pharmacokinetic studies were determined using LC-MS/MS in positive electrospray ionization mode. The LC-MS/MS system consisted of an Agilent 6490 QQQ with a 1290 Infinity HPLC system (Agilent Technologies, Santa Clara, CA, USA). To separate the analytes, SFN and SFN-NAC, from endogenous substances, a SynergiTM 4 μm polar RP 80A column (150 × 2.0 mm, Phenomenex, Torrance, CA, USA) was employed. The LC conditions were as follows: mobile phase, 0.1% formic acid and acetonitrile (50:50); flow rate, 0.2 mL/min; injection volume, 2 μL. Multiple reaction monitoring was achieved with m/z 178.1→114.1 for SFN, m/z 340.9→178.1 for SFN-NAC, and m/z 176.1→111.9 for an internal standard (sulforaphene). Data acquisition and processing were performed using the MassHunter software (version A.06.00, Agilent Technologies). The limit of quantitation was 0.2 ng/mL for SFN and 0.5 ng/mL for SFN-NAC.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!