The largest database of trusted experimental protocols

Lab manager v5

Manufactured by BD
Sourced in Germany

Lab Manager V5.32.0 is a software application designed to manage laboratory operations. It provides tools for data management, workflow organization, and equipment monitoring.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using lab manager v5

1

Respiratory Function Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
In order to collect respiratory function parameters, both gas helium dilution technique and whole-body plethysmography were used. All tests were performed post bronchodilatator.
For the quality of FVC and FEV1 measurements, the American Thoracic Society/European Respiratory Society test criteria for acceptability and repeatability were respected;14 (link) from each spirometry and lung volume at least 3 measurements were taken to assure reproducibility.
Pulmonary function tests (PFTs) were performed using the Master Screen Body (Jaeger, Hoechberg, Germany) equipped with the software Lab Manager V5.32.0 (CareFusion, Hoechberg, Germany).
+ Open protocol
+ Expand
2

Exercise Testing with Cardiopulmonary Monitoring

Check if the same lab product or an alternative is used in the 5 most similar protocols
Incremental and maximal exercise testing was conducted on an electronically-braked cycle ergometer, to a symptom-limited endpoint, with a Jaeger ergospirometry system OxyconPro (CareFusion), and LabManager V5-32.0 software, according to American guidelines11 (link).
The 6-min walk test (6MWT) with continuous SpO2 monitoring and heart frequency was also performed12 .
+ Open protocol
+ Expand
3

Pulmonary Function Testing Protocols

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pulmonary function tests were performed using the plethysmography and diffusing capacity of the lung for carbon monoxide (DLCO) (Master Screen Body Jaeger, Hoechberg, Germany) equipped with the software Lab Manager V5.32.0 (CareFusion, Hoechberg, Germany). For the quality of forced vital capacity (FVC), total lung volume (TLC) and forced expiratory volume in 1 s (FEV1) measurements, the American Thoracic Society/European Respiratory Society test criteria for acceptability and repeatability were respected; from each spirometry and lung volume at least three measurements were taken to assure reproducibility [28 ]. The pulmonary resistance and reactance (5–25 Hz) were measured using IOS (MasterScreen IOS, Viasys GmbH, Hoechberg, Germany). Reactance can be considered as the out of phase component of respiratory impedance, reflecting the balance between inertial and elastic properties of distensible airways. Typically, this is measured at 5 Hz (Xrs5) reflecting the combined effect of tissue elastance and inertance [29 (link), 30 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!