Measuring Cell Viability via MTT Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell viability was measured using a MTT assay. Briefly, cells were seeded in 96-well plates at 3 × 103 cells/well. Before treatment with 5-FU, cells were transfected with indicated siRNAs, miRNA mimic and vectors. After 48 h, cells were treated with different doses of 5-FU for 48 h. Then 10 μl MTT solution was added per well at the concentration of 0.5 μg/μl for 4 h. The resulting Formazan was dissolved in DMSO. After agitation of the plate the absorbance was measured at 570 nm by a Varioscan system (Thermo Fisher).
+ Open protocol
+ Expand
2

Cell Viability Assay in 96-Well Plates

Check if the same lab product or an alternative is used in the 5 most similar protocols
1500 cells were seeded per well into 96-well plates in triplicates. Cell viability was determined using the Cell Counting Kit-8 (CCK-8, Dojindo) or CellTiter-Glo kits (Promega) according to manufacturer's instructions. Absorbance at 450 nm was determined using a Varioscan system (Thermo Fisher).
+ Open protocol
+ Expand
3

MTT Assay for Cell Viability

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were seeded at a density of 3000 cells per well in 96-well plates and treated with salicylate at different concentrations for 48 h. Then, 10 μl of MTT solution was added to each well and incubated for 4 h. This assay is based on reducing MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) by viable cells to form a purple formazan product. Cells were treated with DMSO to release the formazan and the absorbance was measured at 570 nm using a Varioscan system (Thermo Fisher).
+ Open protocol
+ Expand
4

Curcumin Cytotoxicity Evaluation by MTT

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell viability was analyzed by MTT assays. CRC cells were seeded at a density of 3000 cells per well in 96-well plates. After 24 hours, cells were treated with curcumin at the indicated concentrations for 48 hours, followed by addition of 10 μl MTT solution (5 mg/ml) per well and incubation for 4 hours. Cells were lysed with 100 μl DMSO per well for 15 min to release the resulting formazan according to Twentyman et al. [52 (link)], and analyzed by measuring the absorbance at 570 nm by a Varioscan system (Thermo Fisher).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!