The largest database of trusted experimental protocols

Eclipse ti e b microscope

Manufactured by Nikon
Sourced in United Kingdom, Japan

The Nikon Eclipse Ti-E/B is a high-performance inverted microscope designed for advanced imaging and analysis applications. It features a stable and precise mechanical structure, enabling accurate and reproducible observations. The microscope is equipped with a high-resolution optical system and a variety of illumination options to accommodate a wide range of sample types and imaging techniques.

Automatically generated - may contain errors

5 protocols using eclipse ti e b microscope

1

Live Cell Imaging of Transfected HeLa Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mammalian live cell imaging was performed as described earlier [28 (link)]. Briefly, transient transfection of the HeLa Kyoto cells was performed in a 24-well format using lipofectamine reagent according to the manufacturer’s protocol. Cells were cultured using DMEM medium supplemented with 10% FBS, glutamine, 50 U/mL penicillin, and 50 U/mL streptomycin, at 37 °C and 5% CO2. HeLa cell cultures were imaged 24–72 h after the transient transfection using a laser spinning-disk Andor XDi Technology Revolution multi-point confocal system (Andor Technology, Belfast, UK) equipped with an inverted Nikon Eclipse Ti-E/B microscope (Nikon Instruments, Tokyo, Japan), a 75 W mercury–xenon lamp (Hamamatsu, Hamamatsu, Japan), a 60× oil immersion objective NA 1.4 (Nikon, Tokyo, Japan), a 16-bit Neo sCMOS camera (Andor Technology, Belfast, UK), a laser module Revolution 600 (Andor Technology, Belfast, UK), and a spinning-disk module Yokogawa CSU-W1 (Andor Technology, Belfast, UK). The blue, green, and red fluorescence were acquired using the 405, 488, and 561 nm lasers, a confocal dichroic mirror 405/488/561/640, and filter wheel emission filters 447/60, 525/50, and 617/73, respectively. During imaging, the cells were incubated at 37 °C and 5% CO2 using a cage incubator (Okolab, Naples, Italy).
+ Open protocol
+ Expand
2

Live-Cell Imaging of Mammalian Calcium Sensors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Transient transfection of HeLa Kyoto cells and imaging of mammalian cells were performed as described in the Supplementary Methods. The fluorescence of GECIs in the transfected mammalian cells was acquired using a laser spinning-disk Andor XDi Technology Revolution multi-point confocal system (Andor Technology, UK) equipped with an inverted Nikon Eclipse Ti-E/B microscope (Nikon Instruments, Japan), a 75 W mercury–xenon lamp (Hamamatsu, Japan), a 60× oil immersion objective NA 1.4 (Nikon, Japan), a 16-bit Neo sCMOS camera (Andor Technology, UK), laser module Revolution 600 (Andor Technology, UK), and spinning-disk module Yokogawa CSU-W1 (Andor Technology, UK). The green fluorescence intensity of the developed green GECIs and the red fluorescence intensity of the control R-GECO1 red GECI expressed in mammalian cells were acquired using the 488 or 561 nm lasers, confocal dichroic mirror 405/488/561/640 and filter wheel, 525/50 or 617/73 emission filters, respectively. The region of interest (ROI) was chosen in the cytosol of the cell and the value of fluorescence intensity was measured using the Andor iQ3.1 software (Build Number: 7.0.0.74, Belfast, UK). The background values were subtracted for each ROI.
+ Open protocol
+ Expand
3

HeLa Cell Imaging with Confocal Microscopy

Check if the same lab product or an alternative is used in the 5 most similar protocols
HeLa Kyoto cell cultures were imaged 24–48 h after transfection using a laser spinning-disk Andor XDi Technology Revolution multi-point confocal system (Andor Technology, Belfast, UK) equipped with an inverted Nikon Eclipse Ti-E/B microscope (Nikon Instruments, Melville, NY, USA), a 75 W mercury-xenon lamp (Hamamatsu, Iwata City, Japan), a 60× oil immersion objective NA 1.4 (Nikon Instruments, Melville, NY, USA), a 16-bit Neo sCMOS camera (Andor Technology, Belfast, UK), laser module Revolution 600 (Andor Technology, Belfast, UK), spinning-disk module Yokogawa CSU-W1 (Andor Technology, Belfast, UK), and a cage incubator (Okolab, Pozzuoli, Italy). The green and red fluorescence were acquired using 80% of the 488 nm (17.3 µW/cm2 before objective lens) and 80% of 561 nm (62.3 µW/cm2 before objective lens) laser powers, confocal dichroic mirror 405/488/561/640 and filter wheel emission filters 525/50 and 617/73, respectively.
For time-lapse imaging experiments with varying Ca2+ concentration, 2.5 μM ionomycin was added to cells for imaging calcium indicators in the Ca2+-saturated state.
+ Open protocol
+ Expand
4

Nikon Eclipse Ti-E/B Microscopy Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Images were acquired using a Nikon Eclipse Ti-E/B microscope equipped with perfect focus system, a Ti-E TIRF illuminator (CW laser lines: 488 nm, 561 nm, and 640 nm) and a Zyla sCMOS 4.2 camera (Andor, Oxford Instruments, UK) controlled by Andor iQ3 software.
+ Open protocol
+ Expand
5

Fluorescence Microscopy Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Images were acquired using a Nikon Eclipse Ti-E/B microscope equipped with perfect focus system, a Ti-E TIRF illuminator (CW laser lines: 488nm, 561nm and 640nm) and a Zyla sCMOS 4.2 camera (Andor, Oxford Instruments, UK) controlled by Andor iQ3 software (https://andor.oxinst.com/products/iq-live-cell-imaging-software/).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!