The largest database of trusted experimental protocols

Trio trim scanner

Manufactured by Siemens
Sourced in Germany

The Trio Trim scanner is a compact and versatile device designed for precise 3D scanning. It captures high-resolution scans of small to medium-sized objects with a high level of accuracy. The scanner is equipped with a blue LED light source and uses structured light technology to generate detailed 3D point cloud data.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using trio trim scanner

1

MRI and DWI Acquisition Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI data were acquired using a 3.0-T MRI (Siemens Trio Trim scanner) at Korea University Guro Hospital. T1-weighted images were acquired using a magnetization-prepared rapid gradient-echo sequence (TE/TR/TI = 2.32 ms/2.3 s/900 ms; 256 × 256 × 192 matrix for 0.9 mm isovoxels). Multiple DWIs were obtained with a standard single-shot, SE-EPI sequence with eddy current–balanced diffusion-weighting gradient pulses. Two sets of DWIs were collected with 22 additional T2-weighted images, where a single set of DWI consisted of a reference volume and 64 volumes with a gradient direction. The parameters of this imaging protocol were: b = 1000 s/mm2, TE/TR = 100 ms/3.6 s; matrix = 112 × 112 on 230- × 230-mm field of view; 112 × 112 × 75 matrix for 2 mm isovoxels. Adequate signal-to‐noise ratios were provided by the average of the four magnitudes.
+ Open protocol
+ Expand
2

Multimodal Brain Imaging Acquisition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Experiment was performed on a 3-T Siemens TrioTrim scanner, using a standard thirty two-channel phased-array surface coil (Siemens, Erlangen, Germany), which provided high spatial resolution and signal-to-noise ratio. Two functional event-related scans consisting of 625 echoplanar images were acquired using a T2*-weighted gradient-echo pulse sequence with the following parameters: field of view In the structural session, a MPRAGE T1-weighted structural image (1 x 1 x 1 mm resolution) was acquired with the following parameters: TE = 2.97 ms, TR = 2530 ms, flip angle = 7° and FOV = 256 x 256
x 160 mm 3 . This yielded 176 contiguous 1 mm thick slices.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!