The largest database of trusted experimental protocols

2 protocols using rat anti mouse ly6c fitc

1

Murine Corneal Immune Cell Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mice were euthanized at indicated times pi and tissues were harvested. Corneas were digested in RPMI 1640 containing 10% fetal bovine serum (FBS), 1% antibiotic/antimicotic, and gentamicin at 37° C as previously described.28 MLN were dissociated with a 3 ml syringe-plunger head in the presence of media. Cell suspensions were passed through a 40-micron filter before staining. Single cell suspensions were labeled with the following fluorochrome-conjugated monoclonal antibodies: rat anti-mouse CD45 efluor 450, rat anti-mouse CD3e FITC, rat anti-mouse CD4 APC, rat anti-mouse CD8 PE, rat anti-mouse CD3e PE-Cy7, rat anti-mouse NK1.1 FITC, rat anti-mouse CD11b APC, rat anti-mouse Ly6G FITC, rat anti-mouse Ly6C FITC (all from eBioscience), and rat anti-mouse F4/80 APC (Abcam). Labeled cells were washed in 1% BSA in PBS and analyzed using a MACS Quant flow cytometer (Miltenybiotec).
+ Open protocol
+ Expand
2

Murine Corneal Immune Cell Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mice were euthanized at indicated times pi and tissues were harvested. Corneas were digested in RPMI 1640 containing 10% fetal bovine serum (FBS), 1% antibiotic/antimicotic, and gentamicin at 37° C as previously described.28 MLN were dissociated with a 3 ml syringe-plunger head in the presence of media. Cell suspensions were passed through a 40-micron filter before staining. Single cell suspensions were labeled with the following fluorochrome-conjugated monoclonal antibodies: rat anti-mouse CD45 efluor 450, rat anti-mouse CD3e FITC, rat anti-mouse CD4 APC, rat anti-mouse CD8 PE, rat anti-mouse CD3e PE-Cy7, rat anti-mouse NK1.1 FITC, rat anti-mouse CD11b APC, rat anti-mouse Ly6G FITC, rat anti-mouse Ly6C FITC (all from eBioscience), and rat anti-mouse F4/80 APC (Abcam). Labeled cells were washed in 1% BSA in PBS and analyzed using a MACS Quant flow cytometer (Miltenybiotec).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!