Human serpin e1 pai 1 immunoassay

Manufactured by R&D Systems
Sourced in United States

The Human serpin E1/PAI-1 Immunoassay is a quantitative sandwich enzyme-linked immunosorbent assay (ELISA) designed to measure the levels of human serpin E1/PAI-1 in cell culture supernates, serum, and plasma. The assay utilizes a monoclonal antibody specific for human serpin E1/PAI-1 that has been pre-coated onto a microplate.

Automatically generated - may contain errors

4 protocols using human serpin e1 pai 1 immunoassay

1

Biochemical Assessment of Isolated Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Isolated plasma was used in the assessment of a panel of biochemical parameters. The levels of PAI-1 were evaluated via a human SERPINE1/PAI-1 immunoassay (R&D Systems, Minneapolis, MN, USA). The levels of homocysteine were measured using the IMx fluorescence polarizing immunoassay (Abbott Laboratories, Abbott Park, IL, USA), and the levels of folate were measured using a radio-assay kit (ACS:180; Bayer, Tarrytown, NY, USA). Total cholesterol (T. chol) and uric acid levels were determined using commercially available enzymatic colorimetric tests (Roche Diagnostics GmbH, Mannheim, Germany). Platelet (PLT) counts were measured on a Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan). Prothrombin time (PT) and activated partial thromboplastin time (aPTT) were measured using an automated photo-optical coagulometer ACL TOP (Mitsubishi Chemical Medience, Tokyo, Japan).
+ Open protocol
+ Expand
2

Measurement of Blood-Based Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected in anticoagulant containing collection tubes, and the sample tubes were centrifuged for 15 min at 1000× g to separate the plasma from whole blood. The PAI-1 levels were examined by the human Serpin E1/PAI-1 immunoassay (R&D Systems, Minneapolis, MN, USA). Homocysteine levels were measured using the IMx fluorescence polarizing immunoassay (Abbott Laboratories, Abbott Park, IL, USA), and folate levels were measured using a radio-assay kit (ACS:180; Bayer, Tarrytown, NY, USA). Total cholesterol and urate levels were determined using commercially available enzymatic colorimetric tests (Roche Diagnostics GmbH, Mannheim, Germany). Platelet counts were measured on a Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan). Prothrombin time (PT) and activated partial thromboplastin (aPPT) were measured using an automated photo-optical coagulometer ACL TOP (Mitsubishi Chemical Medience, Tokyo, Japan).
+ Open protocol
+ Expand
3

Biomarker Profiling in Blood Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma PAI-1, total cholesterol, uric acid, and homocysteine levels were measured in participant blood samples. Plasma was separated by centrifugation of whole blood at 1000× g for 15 min. PAI-1 levels were determined using a human serpin E1/PAI-1 immunoassay (R&D Systems, Minneapolis, MN, USA). Uric acid and total cholesterol levels were measured using enzymatic colorimetric tests (Roche Diagnostics, GmbH, Mannheim, Germany). Homocysteine levels were measured using a fluorescence polarization immunoassay with an Abbott IMx analyzer (Abbott Laboratories, Abbott Park, IL, USA).
+ Open protocol
+ Expand
4

Biomarkers in Recurrent Pregnancy Loss

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma PAI-1, homocysteine, total cholesterol, and uric acid were measured in blood collected from RPL patients. Plasma was separated by centrifuging whole blood samples at 1000 × g for 15 min. PAI-1 levels were determined using a human serpin E1/PAI-1 immunoassay (R&D Systems, Minneapolis, MN, USA). Uric acid and total cholesterol were measured using commercially available enzymatic colorimetric tests (Roche Diagnostics, GmbH, Mannheim, Germany). Homocysteine was measured using a fluorescence polarization immunoassay using the Abbott IMx analyzer (Abbott Laboratories, Abbott Park, IL, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!