The largest database of trusted experimental protocols

Pylon 100br excelon

Manufactured by Teledyne

The PyLoN-100BR-eXcelon is a back-illuminated CCD detector designed for scientific imaging applications. It features a 1024 x 1024 pixel array with a pixel size of 13 x 13 microns. The detector is cryogenically cooled to reduce dark current and noise, enhancing its performance in low-light conditions. The eXcelon technology provides improved quantum efficiency and reduced interference effects.

Automatically generated - may contain errors

2 protocols using pylon 100br excelon

1

Raman Spectroscopy with Laser Setup

Check if the same lab product or an alternative is used in the 5 most similar protocols
Raman detection unit composed of a spectrometer (Princeton Instruments Acton series SP-2500) and a liquid nitrogen cooled CCD camera (Princeton Instruments PyLoN-100BR-eXcelon) is used for Raman spectra measurements. A Sapphire SF 488 nm laser is applied to the sample with 2 mW laser power.
+ Open protocol
+ Expand
2

Single-Object Photoluminescence Microscopy

Check if the same lab product or an alternative is used in the 5 most similar protocols
Single-object experiments use a home-built micro-PL setup under ambient conditions. The sample is excited using a 594 nm CW diode laser (Cobolt Mambo 100), which is focused on the sample using an oil-immersive microscope objective (NA = 1.42, Olympus PLAPON 60X), mounted on XYZ piezoelectric translational stages (Mad City Labs Inc.) for sample scanning. Luminescence signal is collected using the same objective and focused on a 50 µm pinhole for confocal selection. Spectral selection is performed to remove the excitation beam using a dichroic mirror (zt 594 RDC, Chroma) and a long-pass filter (FELH0600, Thorlabs). After confocal selection, the signal is either directed to silicon-based avalanche photodiodes (SPCM-AQR-13, PerkinElmer) for raster scan measurements, or to a monochromator (SP-2350, Princeton Instruments) coupled to a LN-cooled CCD camera (PyLoN:100BR eXcelon, Princeton Instruments) for spectral measurements. Interface of the translational stages and the detectors with computer uses an acquisition card (PCIe-6323, National Instruments). Raster scans and result display are performed using a python-based suite54 (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!