The largest database of trusted experimental protocols

Ltq velos pro linear ion trap mass spectrometer

Manufactured by Thermo Fisher Scientific
Sourced in United States

The LTQ Velos Pro Linear Ion Trap Mass Spectrometer is a high-performance mass spectrometer designed for advanced analytical applications. It features a linear ion trap that provides high-resolution mass analysis and sensitive detection of a wide range of analytes.

Automatically generated - may contain errors

2 protocols using ltq velos pro linear ion trap mass spectrometer

1

UPLC-MS/MS Quantification of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Vasicine, vasicinone, isoorientin, isovitexin, and apigenin were quantified using a Thermo Vanquish Flex UPLC System interfaced with an LTQ Velos Pro Linear Ion Trap Mass Spectrometer (ThermoFisher, San Jose, CA, USA). Chromatographic separation of the analytes was achieved using a BEH C18 column (150 × 3 mm i.d.; 1.7 μm particle size; Waters, Milford, MA) at 50 °C with gradient elution. The mobile phases were (A) 0.1% formic acid in H2O and (B) methanol and a flow rate of 300 mL/minute. The percentage of B varied as follows: 2% B at 0 min, 2%→95% (0 to 7.5 min), hold at 95% (7.5 to 8.5 min), 95%→2% (8.5 to 8.6 min), and hold at 2% from 8.6 to 10 min. A convex gradient (setting = 6 during the 0–7.5 min ramp) was used. The mass spectrometer was operated in positive electrospray ionization, selective reaction-monitoring mode. The MS/MS parameters were optimized by infusion of vasicine into the MS/MS system and the following precursor→product transitions were used: m/z 189.1→m/z 171.1 for vasicine, m/z 203.2→m/z 185.1 for vasicinone, m/z 449.1→m/z 431.1 for isoorientin, m/z 433.2→m/z 415.1 for isovitexin, and m/z 271.1→m/z 271.1 + 243.1 for apigenin. Data acquisition and processing were performed using Xcalibur software, and calibration curves were prepared in water using analyte peak area versus concentration.
+ Open protocol
+ Expand
2

Carbohydrate Analysis by LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
An Ultimate 3000 RS Dionex system (Thermo Fisher Scientific, MA, US) composed by quaternary pump, autosampler and column compartment, was used. It was coupled with an LTQ velos PRO Linear Ion Trap mass spectrometer by an elctrospary interface H-ESI (Thermo Fisher Scientific). The column was Prevail™ Carbohydrate ES 5µm, 2.1 x 150 mm thermostated at 35°C. Chromatographyc conditions were: isocratic elution with acetonitrile and ammonium formiate 5mM 70:30 (v/v), at a flow rate of 0.3 mL/min; ESI temperature 290°C, sheath gas flow 30 psi, aux gas 15 (arbitrary units), spray voltage -2.8kV, capillary temperature 320°C. Data acquisition and analysis were performed using Trace Finder software v. 3.2 (Thermo Fisher).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.