Type 5975 c

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 5975 C is a gas chromatography-mass spectrometry (GC-MS) system designed for analytical applications. It features a triple-axis mass spectrometer and an inert ion source to provide high sensitivity and selectivity for the identification and quantification of compounds in various samples.

Automatically generated - may contain errors

2 protocols using type 5975 c

1

Comprehensive VOC Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
VOCs were analyzed using the industrial standard methods for air and particulate monitoring77 ,78 . The VOC concentration was measured using a thermal desorbed instrument (Tekmar 6000/6016) interfaced with a gas chromatograph (HP 7890 B) and mass selective detector (HP 5977 A, AMA Co., Germany). The working conditions of the TDS were as follows: gas pressure of 20 kPa, inlet temperature of 250 °C desorption temperature of 250 °C for 10 min; cold trap temperature held at 120 C for 3 min, followed by a rapid increase to 260 °C. An HP-5MS column (50 m, i.d. 0.25 mm, and film thickness 0.25 m) was used for chromatographic separation. The temperature program was 40 °C for 3 min followed by 10 °C/min up to 250 °C for 3 min and then an increase to 270 °C. The ion energy of the MS (type 5975 C, Agilent) was 70 eV; the ion source temperature was 230 °C; the Quadrupole temperature and the interface temperature were 150 and 280 °C, respectively; and the mass spectrometry scanning mass ranged from 28 to 450 m/z. The retrieval and qualitative analysis of the mass spectrometry data were accomplished using the NIST 2008 library, which was housed in the computer of the temperature instrument. In addition, the chromatographic peak area normalization method was used for the calculation of the relative concentrations of the mass spectrometry data.
+ Open protocol
+ Expand
2

Quantifying Fecal Short-Chain Fatty Acids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Stool SCFAs were measured using a gas chromatography-mass spectrometry (GC-MS; Gas chromatograph (type 7890A, Agilent, USA) equipped with a mass selective detector (type 5975C, Agilent, USA). The measurement details were described in our previous study (30 (link)) and Supplementary File 1. The standards, including acetate-d3, propionate-d5, butyrate-d7, valerate-d9, isobutyric acid, 2-methylbutyric acid, and 3-methylbutyric acid (isovaleric acid), were purchased from Sigma (St. Louis, MO, USA). A set of diluted standards was prepared (1,000 μg/mL, 100 μg/mL, 10 μg/mL, 1 μg/mL, 0.1 μg/mL, and 0.01 μg/mL) with ethyl acetate before analysis. Data analysis was performed with ChemStation (Agilent, CA, USA, v E.02.02.1432) and Chroma TOF software (LECO, St. Joseph, MI, USA, v 4.34). SCFA concentrations in fecal samples were reported in milligrams per gram (mg/g) of feces.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!