The largest database of trusted experimental protocols

32 channel high resolution phased array coil

Manufactured by Siemens
Sourced in United States, Germany

The 32-channel high-resolution phased-array coil is a specialized lab equipment designed for magnetic resonance imaging (MRI) applications. It features a multi-channel array of coils that work together to capture high-quality, high-resolution images. The core function of this product is to enhance the signal-to-noise ratio and spatial resolution of MRI scans, enabling more detailed and accurate imaging for research and diagnostic purposes.

Automatically generated - may contain errors

2 protocols using 32 channel high resolution phased array coil

1

High-resolution 3D MRI brain scans

Check if the same lab product or an alternative is used in the 5 most similar protocols
Three-dimensional structural MRI scans were acquired using a 3.0 Tesla Siemens Trio whole-body imaging system (Siemens Medical Systems, Iselin, NJ, USA), using a dedicated 32-channel high-resolution phased-array coil for brain imaging. T1-weighted images were acquired parallel to the anterior commissure-posterior commissure line using T1-weighted magnetization-prepared rapid gradient-echo imaging (repetition time=1,900 ms, echo time=2.6 ms, field of view=220 mm, 256×256 matrix size, 176 coronal slices without gap, 1×1×1 mm3 voxels, flip angle=16°, and number of excitations=1).
+ Open protocol
+ Expand
2

Brain Imaging with Siemens Skyra 3T MRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
All volunteers were scanned with a Siemens Skyra 3.0 T MRI scanner (Siemens Healthineers, Erlangen, Germany) using a 32-channel high-resolution phased array coil in the Nansha Imaging Center of Guangzhou First People’s Hospital. None of the participants were taking any medication that might have influenced cognition during the scans at the time of the study. The volunteers laid in a supine position with their heads fixed snugly with foam pads to minimize head motion. MRI sequences included 3D T1-weighted imaging and 3D SWI. An axial orientation parallel to the anterior commissure to the posterior commissure (AC-PC) line in all sequences covered the entire brain. T1-weighted imaging was performed under the following parameters: repetition time (TR) =2,530 ms, echo time (TE) =2.96 ms, slice thickness =1.0 mm, flip angle =7°, field of view =256×256 mm2, and acquisition matrix =352×352. SWI was performed with the following parameters: TR =28 ms, TE =20 ms, slice thickness =1.0 mm, flip angle =15°, field of view (FOV) =220×193.8 mm2, and acquisition matrix =352×352.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!