The largest database of trusted experimental protocols

Cxcl10 elisa kit

Manufactured by R&D Systems
Sourced in United States

The CXCL10 ELISA Kits are quantitative sandwich enzyme-linked immunosorbent assay (ELISA) designed for the detection and quantification of CXCL10 in various biological samples. The kit utilizes a specific monoclonal antibody pre-coated onto a microplate. CXCL10 in the sample is bound to the immobilized antibody and then detected using a biotinylated polyclonal detection antibody and streptavidin-peroxidase conjugate.

Automatically generated - may contain errors

5 protocols using cxcl10 elisa kit

1

Immune Response Assays for Cell Activation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following were utilized in this study: G6PD activity assay kit (Abcam #ab176722), PGD activity assay kit (Abcam #ab273328), NETosis assay kit (Cayman #601010), ROS detection assay kit (Cayman #601290), mouse VEGF kit (Thermo Fisher Scientific, #KHG0111 & #MMV00), mouse TNFα kit (Thermo Fisher Scientific, #BMS223-4 & #MTA00B), Phagocytosis assay kit (Cell Biolabs #CBA-222), Mouse Syndecan-1 ELISA kit (Abcam #ab273165), ICAM-1 ELISA kit (R&D Systems #MIC100), CXCL10 ELISA kit (R&D Systems #DY466-05), IL-8 ELISA kit (MyBioSource #MBS7606860), and CXCR2 ELISA kit (MyBioSource #MBS726530). All experiment assays followed the manufacturers’ instructions as done by us previously95 (link). Treated cells were put in a serum-free medium and stimulated with LPS (1 μg/ml) for 3 hrs before assay ROS, VEGF, and TNF.
+ Open protocol
+ Expand
2

Cytokine Measurement Protocols

Check if the same lab product or an alternative is used in the 5 most similar protocols
IL-10, CXCL10 and IL-27 production were measured using an IL-10 ELISA kit from BD, a CXCL10 ELISA kit from R&D, or anti-mouse IL-27p28 and biotin-conjugated anti-mouse IL-27p28 antibodies from R&D (Minneapolis, MN, USA) as described in [25 (link)]. Alternatively, IL-27 was also measured by mouse IL-27 ELISA Ready-Set-Go! Kit from eBioscience, following manufacturer’s instructions.
+ Open protocol
+ Expand
3

Mitochondrial Dysfunction in Immune Signaling

Check if the same lab product or an alternative is used in the 5 most similar protocols
A list of all reagents, chemicals or kits used in this study can be found in Table S1. Lipopolysaccharide (LPS) and high molecular weight Poly(I:C) (PIC) were purchased from InvivoGen. MitoTEMPO (MT), N-acetylcysteine (NAC), antimycin A (AA), rotenone (ROT), potassium cyanide, 2-deoxyglucose (2-DG), oligomycin (OM) and carbonyl cyanide-p-trifluoromethoxyphenylhydrazone (FCCP) were acquired from Sigma-Aldrich while S3QEL-2 was purchased from Cedarlane. IL-1β, IL-6, IL-10, TNF-α, and CXCL10 ELISA kits were purchased from R&D Systems. The IFN-α/IFN-β 2-Plex Mouse ProcartaPlexTM Luminex Panel kit used was from Invitrogen. Tetramethylrhodamine, methyl ester (TMRM), MitoSox Red and CellROX Orange probes were from ThermoFisher. Antibodies against Complex II (SDHB) was from Abcam while antibodies recognizing SOD2 was purchased from Cell Signalling Technology. Antibodies targeting IRF3, pIRF3 (Ser385), IRF7, pIRF7 (Ser477), GPX4, Iκbα, Complexes I (NDUFB8), III (UQCRC2) and IV (COX4) were purchased from ThermoFisher.
+ Open protocol
+ Expand
4

Poly-IC and Interferon-Based Cancer Immunotherapy

Check if the same lab product or an alternative is used in the 5 most similar protocols
PICLC (Hiltonol) is a clinical grade formulation of poly-IC stabilized with poly-L-lysine and carboxymethylcellulose manufactured by Oncovir. High molecular weight (hmw) poly-IC and poly-AU were purchased from InvivoGen. Poly-IC/PEI was prepared by mixing hmw poly-IC with in vivo-JetPEI (Polyplus) at a nucleotide:PEI ratio of 6 in a 5% glucose solution. Antimouse PD-L1 monoclonal antibody (mAb) (clone, 10F.9G2) was from BioXcell. Mouse recombinant Interferon-beta and human recombinant Interferon-α2 were purchased from BioLegend. CXCL10 ELISA kits were purchased from R&D Systems. EliSpot plates were from eBioSciences. Dispase I (neutral protease, grade I) was purchased from Sigma-Aldrich. Fluorescence-conjugated Abs for flow cytometry were from Biolegend or eBioscience.
+ Open protocol
+ Expand
5

Cytokine Quantification via ELISA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Concentrations of IL-6 and IL-12p40 were measured using antibodies obtained from BD Biosciences. IFN-β was detected using antibodies from Santa Cruz and Interferome. CXCL10 ELISA kits were purchased from R&D systems.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!