Spectrum 400 ft ir fir spectrometer

Manufactured by PerkinElmer
Sourced in United States

The Spectrum 400 FT-IR/FIR spectrometer is a versatile laboratory instrument designed for the analysis of a wide range of samples. It is capable of performing Fourier Transform Infrared (FT-IR) and Far-Infrared (FIR) spectroscopy, which are analytical techniques used to identify and characterize chemical compounds based on their unique molecular vibrations.

Automatically generated - may contain errors

3 protocols using spectrum 400 ft ir fir spectrometer

1

Characterization of Multiwalled Carbon Nanotubes

Check if the same lab product or an alternative is used in the 5 most similar protocols
The characterization of the MWCNT structure was analyzed using field-emission scanning electron microscope (FE-SEM, SU 8010, Hitachi). Energy dispersive x-ray spectrum (EDX) analysis was performed to quantify the elements of the sample which was also verified by elemental analysis on a CHNS–O elemental analyser (Flash 2000, Thermo Scientific). FTIR spectra were carried out on a Spectrum 400 FT-IR/FIR spectrometer (Perkin Elmer). Agglomeration studies were performed using visual observation after dispersing 1 mg of the various MWCNTs in 10 ml of MiliQ water and in 10 ml of DMEM (10 % FBS supplemented) to replicate the culture medium conditions and leaving them undisturbed for 7 days. Subsequently, the aqueous MWCNT samples after bath sonication were subjected to zeta potential analysis for estimation of charge to size ratio of the dispersed/dissolved nanoparticles.
+ Open protocol
+ Expand
2

Analytical Characterization of Drug-Loaded SLNs

Check if the same lab product or an alternative is used in the 5 most similar protocols
In vitro profiling and thermal analysis of pure drug and produced SLNs were performed using a UV-Visible spectrophotometer (Shimadzu, UV-1800) and DSC Q200 (TA Instruments Trios V4.1, USA). The particle size (PS), zeta potential, and polydispersity index (PDI) were determined using Zetasizer (Malvern Zetasizer, Ver. 7.11). The transmission electron microscope (TEM) was used to study the morphology of the optimized formulation (H-7500, Hitachi Ltd., and Japan). A molecular weight cutoff of 12–14 kDa was used in in vitro research that involved the use of dialysis membranes (Himedia, Mumbai, India). Spectrum 400 FTIR/FIR Spectrometer, Perkin Elmer, and USA spectrophotometer were used in the FTIR (Fourier-transform infrared) investigation.
+ Open protocol
+ Expand
3

FTIR Analysis of THC-SLN Formulation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Spectrum 400 FT-IR/FIR Spectrometer, Perkin Elmer, USA was used for FTIR Study of THC, GMS, their physical mixture, and the lyophilized optimized THC-SLN using KBr pellet system. The absorption bands with characteristic peaks were obtained in the range of 4000–650 cm−1.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!