The largest database of trusted experimental protocols

4 protocols using mpeg mn 2000

1

Synthesis and Characterization of THA Loaded PLGA Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
THA (≥98%) was purchased from Meilun Biotech Co. Ltd (Dalian, People’s Republic of China). ε-Caprolactone (ε-CL) was purchased from Alfa Aesar (Ward Hill, MA, USA). MPEG (Mn =2,000), stannous octoate [Sn(Oct)2], and MTT were purchased from Sigma-Aldrich Co. (St Louis, MO, USA). Dimethyl sulfoxide (DMSO), methyl alcohol, and acetonitrile (HPLC grade) were supplied by Kelong Co. Ltd. (Chengdu, People’s Republic of China). A TNF-α ELISA kit was purchased from Beijing Cheng Lin Biological Technology Co. Ltd. (Beijing, People’s Republic of China). Ki-67, CD31, and VEGF polyclonal antibody were purchased from Bioworld Technology Co. Ltd. (Nanjing, People’s Republic of China).
+ Open protocol
+ Expand
2

Synthesis and Characterization of CSPIO

Check if the same lab product or an alternative is used in the 5 most similar protocols
mPEG (Mn 2000) and l-alanine were purchased from Sigma-Aldrich (St Louis, MO, USA). Trifluoroacetic acid-d (TFA-d) and trifluoroacetic acid (TFA) were purchased from Alfa Aesar (Wall Hill, MA, USA). Ammonium hydroxide solution (28–30%), diethyl ether, toluene, hexane, and ethanol (95%) were purchased from Echo Chemicals (Toufen, Miaoli, Taiwan). Dimethyl sulfoxide (DMSO) was obtained from J.T. Baker (Center Valley, PA, USA). Dulbecco’s modified eagle’s medium (DMEM), fetal bovine serum (FBS), and antimycotic antibiotics were purchased from Gibco (Grand Island, NY, USA). Tetrahydrofuran (THF) was purchased from TEDIA (Fairfield, OH, USA); dichloromethane (DCM), N,N-dimethylformamide (DMF), and chloroform were obtained from AVANTOR (Center Valley, PA, USA) and dried over CaH2 before being used. CSPIO was prepared via a chemical co-precipitation method [30 (link)].
+ Open protocol
+ Expand
3

Polymer Synthesis and Cellular Assays

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ola with 99.8% purity was purchased from Meilun Co., Ltd (Dalian, China). MPEG (Mn =2,000) was purchased from Sigma-Aldrich (St Louis, MO, USA), ε-caprolactone from Alfa Aesar (Reston, VA, USA), and stannous octoate (Sn(Oct)2) purchased from Sigma-Aldrich. Dimethylsulfoxide (DMSO), anhydrous ethanol, and methanol (HPLC grade) were purchased from KeLong Co., Ltd (Chengdu, China). γ-H2AX, CC3, Ki-67, and CD-31 polyclonal antibodies were purchased from Bioworld Technology Co. Ltd. (Nanjing, China).
+ Open protocol
+ Expand
4

Synthesis and Characterization of Chitosan-Coated Superparamagnetic Iron Oxide Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
ʟ-alanine and mPEG (Mn 2000) were purchased from Sigma-Aldrich (St Louis, MO, USA). Trifluoroacetic acid (TFA) and trifluoroacetic acid-d (TFA-d) were purchased from Alfa Aesar (Wall Hill, MA, USA). Ammonium hydroxide solution (28–30%), toluene, hexane, diethyl ether, and 95% ethanol were purchased from Echo Chemicals (Toufen, Miaoli, Taiwan). Dimethyl sulfoxide (DMSO) was purchased from J.T. Baker (Center Valley, PA, USA). Dulbecco’s modified Eagle’s medium (DMEM), fetal bovine serum (FBS), and antimycotic antibiotics were purchased from Gibco (Grand Island, NY, USA). Tetrahydrofuran (THF) was purchased from TEDIA (Fairfield, OH, USA); dichloromethane (DCM), N,N-dimethylformamide (DMF), and chloroform were obtained from AVANTOR (Center Valley, PA, USA) and dried over CaH2 before being used. Chitosan-coated superparamagnetic iron oxide (CSPIO) was prepared with a chemical co-precipitation method [29 (link)]. Prussian blue and anti-CD31 antibody were purchased from Thermo Fisher (Cheshire, UK). Anti-Ki67 antibody and anti-alpha smooth muscle actin (SMA) antibody were purchased from Abcam (Cambridge, UK).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!