The largest database of trusted experimental protocols

4 protocols using ab119597

1

Renal Function Evaluation via Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Renal function was evaluated via assessing serum levels of creatinine (Cr; ab700460), uric acid (ab65344), blood urea nitrogen (BUN; ab83362), lactate dehydrogenase (LDH; ab102526), and kidney injury molecule-1 (Kim-1; ab119597) using the specified colorimetric or ELISA kit obtained from Abcam Inc. (Waltham, MA, USA), agreeing with the manufacturer’s practices consuming a spectrophotometer (LEICA UNISTAT®; Leica Inc., Allendale, NJ, USA).
+ Open protocol
+ Expand
2

Kidney Injury Biomarker Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
There were four groups in the experiment: a control group, an AngII group, a CMS group, and a RES group. The cells were cultured as earlier described, and KIM-1 and neutrophil gelatinase-associated lipocalin (NGAL) abundance in the supernatant was determined by ELISA kits obtained from R&D Systems (DLCN20, Minneapolis, MN, United States) and Abcam (ab119597). All of the operational procedures were performed in accordance with the manufacturers’ instruction.
+ Open protocol
+ Expand
3

Serum Biomarkers for Kidney Injury

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood biochemical analysis was performed according to previous investigations. The blood samples were extracted 24 h following sham or CLP operation and centrifuged at 1400 x g to prepare serum at 4°C for 10 min. SCr levels were evaluated by a creatinine enzymatic assay kit (MAK080-1KT, Sigma-Aldrich, Merck KGaA) and measured at 570 nm. BUN was detected with an enzymatic assay kit (MAK006-1KT, Sigma-Aldrich, Merck KGaA) and measured at 570 nm. The expression levels of NGAL (ab119602, Abcam) and KIM-1(ab119597, Abcam) were measured using corresponding kits and measured at 450 nm. All measurements were conducted with a multiscan spectrum spectrophotometer (Thermo Fisher Scientific Inc.)
+ Open protocol
+ Expand
4

Quantification of NGAL and KIM-1 in Urine

Check if the same lab product or an alternative is used in the 5 most similar protocols
Levels of neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule (KIM)-1 in rat urine and cell culture supernatants were measured with Quantikine ELISA kits purchased from R&D Systems (DLCN20; Minneapolis, MN, USA) and Abcam (ab119597; Cambridge, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!