Q exactive hf qe hf mass spectrometer

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Q Exactive HF (QE-HF) is a high-resolution, high-mass accuracy mass spectrometer designed for advanced proteomics, metabolomics, and small molecule analysis. It features a quadrupole mass filter, an Orbitrap mass analyzer, and a high-energy collision dissociation (HCD) cell for tandem mass spectrometry (MS/MS) analysis. The QE-HF provides fast scanning speeds, high resolving power, and exceptional mass accuracy to enable comprehensive analysis of complex samples.

Automatically generated - may contain errors

2 protocols using q exactive hf qe hf mass spectrometer

1

Quantifying Cysteine and Glutathione Pools

Check if the same lab product or an alternative is used in the 5 most similar protocols
For determination of the relative Cys and GSH pool sizes across compartments, previously established LC-MS conditions were employed5 (link),24 For chromatographic metabolite separation, a Vanquish UPLC system was coupled to a Q Exactive HF (QE-HF) mass spectrometer equipped with HESI (Thermo Fisher Scientific, Waltham, MA, USA). Samples were run on an Atlantis Premier BEH Z-HILIC VanGuard FIT column, 2.5 µm, 2.1 mm × 150 mm (Waters, Milford, MA, USA). The mobile phase A was 10 mM (NH4)2CO3 and 0.05% NH4OH in H2O, while mobile phase B was 100% ACN. The column chamber temperature was set to 30 °C. The mobile phase condition was set according to the following gradient: 0-13 min: 80% to 20% of mobile phase B, 13–15 min: 20% of mobile phase B. The ESI ionization mode was negative, and the MS scan range (m/z) was set to 65-975. The mass resolution was 120,000 and the AGC target was 3 × 106. The capillary voltage and capillary temperature were set to 3.5 kV and 320 °C, respectively. 5 μL of sample was loaded. For each experimental run, 5 μL of extraction solvent were run in triplicate as blank controls; these were disbursed throughout the run to signal changes in the integrity of metabolite detection. The LC-MS metabolite peaks were manually identified and integrated by El-Maven (Version 0.10.0) by matching with a previously established in-house library5 (link).
+ Open protocol
+ Expand
2

Metabolite Separation and Analysis by LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The LC-MS conditions were identical to previously established methods [62 ]. For the chromatographic metabolite separation, the Vanquish UPLC systems were coupled to a Q Exactive HF (QE-HF) mass spectrometer equipped with HESI (Thermo Fisher Scientific, Waltham, MA). The column was a SeQuant ZIC-pHILIC LC column, 5 μm, 150 × 4.6 mm (MilliporeSigma, Burlington, MA) with a SeQuant ZIC-pHILIC guard column, 20 × 4.6 mm (MilliporeSigma, Burlington, MA). Mobile phase A was 10 mM (NH4)2CO3 and 0.05% NH4OH in H2O while mobile phase B was 100% ACN. The column chamber temperature was set to 30 °C. The mobile phase condition was set according to the following gradient: 0–13 min: 80%–20% of mobile phase B, 13–15 min: 20% of mobile phase B. The ESI ionization mode was negative. The MS scan range (m/z) was set to 60–900. The mass resolution was 120,000 and the AGC target was 3 × 106. The capillary voltage and capillary temperature were set to 3.5 KV and 320 °C, respectively. 5 μL of sample was loaded. For the non-targeted metabolomics approach, the LC-MS peaks were automatically extracted and aligned using the Automated Feature Detection function of EL-Maven. After the normalization with the median value of the intensities of LC-MS peaks, the statistical analysis was conducted. For the isotope tracing experiment, the natural abundance isotope correction was performed using EL-Maven.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!