The largest database of trusted experimental protocols

4 protocols using hydroxytyrosol

1

Analytical Standards for Phenolic Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ultrapure water was obtained through a purification system (Millipore Direct-Q UV, Bedford, MA, USA). Formic acid, of LC-MS grade, and ammonium acetate ≥99% were obtained from Fluka (Buchs, Switzerland). Sodium hydroxide >99% and methanol, of LC-MS grade, were acquired from Merck (Darmstadt, Germany). 2-propanol was acquired from Fisher Scientific (Geel, Belgium).
All standards had an analytical grade ≥95%. Epicatechin, ferulic acid, gallic acid, homovanillic acid, oleuropein, pinoresinol, p-coumaric acid, and syringaldehyde were purchased from Sigma-Aldrich (Steinheim, Germany). Apigenin, caffeic acid, tyrosol, and vanillin were acquired from Alfa Aesar (Karlsruhe, Germany). Luteolin and hydroxytyrosol were purchased from Santa Cruz Biotechnologies (Heidelberg, Germany). Syringic acid was obtained from Extrasynthèse (Genay, France). Stock solutions for each analyte (1000 mg/L) were dissolved in methanol and stored at −20 °C. Mixed standard working solutions were prepared every laboratory day diluting the stock solutions with water:methanol (20:80, v/v).
+ Open protocol
+ Expand
2

Quantitative Analysis of Polyphenols

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methanol (LC-MS grade) and sodium hydroxide (>99%) were purchased from Merck (Darmstadt, Germany). Ammonium acetate (≥99% for HPLC) and formic acid (LC-MS Ultra) were purchased from Fluka (Buchs, Switzerland). Isopropanol was obtained from Fisher Scientific (Geel, Belgium). Ultrapure water was provided by a Milli-Q purification apparatus (Millipore Direct-Q UV, Bedford, MA, USA). Regarding the standards that were used, syringic acid 95% was purchased from Extrasynthèse (Genay, France). Gallic acid 98%, ferulic acid 98%, epicatechin 97%, p-coumaric (4-hydroxycinnamic acid) 98%, homovanillic acid 97%, quercetin 98%, oleuropein 98%, pinoresinol 95%, caffeic acid 99%, taxifolin 98%, vanillic acid 97% and syringaldehyde 98% (internal standard) were obtained from Sigma-Aldrich (Steinheim, Germany). Hydroxytyrosol 98% and luteolin 98% were acquired from Santa Cruz Biotechnologies. Vanillin 99%, apigenin (4,5,7-trihydroxyflavone) 97% and tyrosol (2-(4-hydroxyphenyl) ethanol) 98% were purchased from Alfa Aesar (Karlsruhe, Germany). Stock standard solutions of individual compounds (1000 mg/L) were solubilized in methanol and stored at −20 °C in dark brown glass bottles. Intermediate standard working solutions containing the analytes were prepared by appropriate dilution of the stock solutions with methanol:water (80:20, v/v) over the concentration range 0.1–8 mg/L.
+ Open protocol
+ Expand
3

Comprehensive Wine Polyphenol Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
All standards and reagents were LC-MS grade and were used without any further treatments. Authentic standards of 2,5-Dihydroxybenzoic acid (gentisic acid), 3,4-dihydroxybenzoic acid (protocatechuic acid), 4-hydroxybenzoic acid, cinnamic acid, epicatechin, eriodictyol, ferulic acid, gallic acid, myricetin, p-coumaric acid, pinoresinol, quercetin, resveratrol, rosmarinic acid, salicylic acid, syringic acid, taxifolin, and vanillic acid were purchased from Sigma-Aldrich (Stenheim, Germany). Apigenin, caffeic acid, catechin, ethyl vanillin (internal standard, IS), galangin, genistein, naringenin, tyrosol, and vanillin were acquired from Alfa Aesar (Karlsruche, Germany), whereas hydroxytyrosol and luteolin were obtained from Santa Cruz Biotechnology (Santa Cruz, CA, USA).
2-Propanol (LC–MS grade) and methanol (MeOH) (LC–MS grade) were purchased from Fisher Scientific (Geel, Belgium) and Merck (Darmstadt, Germany), respectively. Formic acid 99%, ammonium acetate and sodium hydroxide monohydrate for trace analysis ≥ 99.9995% were all obtained from Fluka (Buchs, Switzerland). Ultrapure water (18.2 MΩ resistivity) was provided by a Millipore Direct-Q UV purification System (Millipore, Bedford, MA, USA). The wine samples were filtered using regenerated cellulose syringe filters (RC filters, pore size 0.2 μm, diameter 15 mm) purchased from Phenomenex (Torrance, CA, USA).
+ Open protocol
+ Expand
4

LC-MS Analysis of Polyphenol Standards

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methanol (LC-MS grade) and sodium hydroxide (>99%) were acquired from Merck (Darmstadt, Germany). Ammonium acetate (≥99%) and formic acid (LC-MS Ultra) were purchased from Fluka (Buchs, Switzerland). Isopropanol was obtained from Fisher Scientific (Geel, Belgium). Ultrapure water was obtained using a Milli-Q purification system (Millipore Direct-Q UV, Bedford, MA, USA).
Syringic acid 95% was purchased from Extrasynthèse (Genay, France). Gallic acid 98%, ferulic acid 98%, epicatechin 97%, p-coumaric 98%, oleuropein 98%, homovanillic acid 97%, syringaldehyde 98%, and pinoresinol 95% were purchased from Sigma-Aldrich (Steinheim, Germany). Hydroxytyrosol 98% and luteolin 98% were acquired from Santa Cruz Biotechnologies. Caffeic acid 99%, vanillin 99%, apigenin 97%, and tyrosol 98% were purchased from Alfa Aesar (Karlsruhe, Germany). Stock standard solutions of each analyte (1000 mg/L) were solubilized in methanol and stored at −20 °C in dark brown glass bottles. Mixed standard working solutions were prepared every laboratory day by appropriate dilution of the stock solutions with methanol:water (80:20, v/v) in the concentration range of 0.1–12 mg/L.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.