The largest database of trusted experimental protocols

10 protocols using methacrylic acid

1

Synthesis of Block Copolymer from Benzyl Methacrylate and Methacrylic Acid

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 4

In a nitrogen-replaced glove box, 90 g (511 mmol) of benzyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 3.00 g (10.0 mmol) of BTEE, 1.85 g (5.0 mmol) of DBDT, 0.33 g (2.00 mmol) of AIBN, and 90 g of methoxypropanol were charged into a flask equipped with a stirrer, and then reacted at 60° C. for 23 hours. The polymerization rate was 99.8%, the Mw was 11,800, and the PDI was 1.41.

45 g (317 mmol) of butyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 25 g (290 mmol) of methacrylic acid (manufactured by Tokyo Chemical Industry Co., Ltd.), 0.22 g (1.33 mmol) of AIBN, and 70 g of methoxypropanol were added to the obtained solution, and then reacted at 60° C. for 21 hours. The polymerization rate was 99.1%.

After completion of the reaction, the reaction solution was poured into 5 L of heptane, the produced precipitate was suction-filtrated, and then dried, thereby obtaining 155.2 g (yield: 97%) of white powdery block copolymer B. The acid value was 102. The Mw and the PDI were measured after a carboxylic component in the block copolymer was methyl-esterified. The Mw was 17,300 and the PDI was 1.31.

+ Open protocol
+ Expand
2

Synthesis of Benzyl Methacrylate-Butyl Methacrylate-Methacrylic Acid Block Copolymer

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 7

In a nitrogen-replaced glove box, 90 g (511 mmol) of benzyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 2.00 g (6.67 mmol) of BTEE, 1.23 g (3.33 mmol) of DBDT, 0.33 g (1.33 mmol) of AIBN, and 90 g of methoxypropanol were charged into a flask equipped with a stirrer, and then reacted at 60° C. for 24 hours. The polymerization rate was 99.3%, the Mw was 17,200, and the PDI was 1.45.

48 g (338 mmol) of butyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 22 g (256 mmol) of methacrylic acid (manufactured by Tokyo Chemical Industry Co., Ltd.), 0.22 g (0.67 mmol) of AIBN, and 70 g of methoxypropanol were added to the obtained solution, and then reacted at 60° C. for 24 hours. The polymerization rate was 98.9%.

After completion of the reaction, the reaction solution was poured into 5 L of heptane, the produced precipitate was suction-filtrated, and then dried, thereby obtaining 153.3 g (yield: 96%) of white powdery block copolymer E. The acid value was 90. The Mw and the PDI were measured after a carboxylic component in the block copolymer was methyl-esterified. The Mw was 25,100 and the PDI was 1.29.

+ Open protocol
+ Expand
3

Synthesis of Block Copolymer A

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

In a nitrogen-replaced glove box, 90 g (511 mmol) of benzyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 2.00 g (6.67 mmol) of BTEE, 1.22 g (3.33 mmol) of DBDT, 0.33 g (2.00 mmol) of 2,2′-azobis-isobutyronitrile (trade name: AIBN, manufactured by Otsuka Chemical Co., Ltd., hereinafter referred to as “AIBN”), and 90 g of methoxypropanol were charged into a flask equipped with a stirrer, and then reacted at 60° C. for 16 hours. The polymerization rate was 99.6%, the Mw was 16,200, and the PDI was 1.41.

45 g (317 mmol) of butyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 25 g (290 mmol) of methacrylic acid (manufactured by Tokyo Chemical Industry Co., Ltd.), 0.22 g (1.33 mmol) of AIBN, and 70 g of methoxypropanol were added to the obtained solution, and then reacted at 60° C. for 22 hours. The polymerization rate was 99.1%.

After completion of the reaction, the reaction solution was poured into 5 L of heptane, the produced precipitate was suction-filtrated, and then dried, thereby obtaining 138.2 g (yield: 86%) of white powdery block copolymer A. The acid value was 104. The Mw and the PDI were measured after a carboxylic component in the block copolymer was methyl-esterified. The Mw was 24,300 and the PDI was 1.49.

+ Open protocol
+ Expand
4

Synthesis of Block Copolymer C

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 5

In a nitrogen-replaced glove box, 90 g (511 mmol) of benzyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 1.50 g (5.0 mmol) of BTEE, 0.92 g (2.5 mmol) of DBDT, 0.25 g (1.50 mmol) of AIBN, and 90 g of methoxypropanol were charged into a flask equipped with a stirrer, and then reacted at 60° C. for 23 hours. The polymerization rate was 99.9%, the Mw was 21,500, and the PDI was 1.46.

45 g (317 mmol) of butyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 25 g (290 mmol) of methacrylic acid (manufactured by Tokyo Chemical Industry Co., Ltd.), 0.16 g (1.00 mmol) of AIBN, and 70 g of methoxypropanol were added to the obtained solution, and then reacted at 60° C. for 21 hours. The polymerization rate was 99.0%.

After completion of the reaction, the reaction solution was poured into 5 L of heptane, the produced precipitate was suction-filtrated, and then dried, thereby obtaining 157.9 g (yield: 99%) of white powdery block copolymer C. The acid value was 100. The Mw and the PDI were measured after a carboxylic component in the block copolymer was methyl-esterified. The Mw was 29,000 and the PDI was 1.39.

+ Open protocol
+ Expand
5

Synthesis of Block Copolymer F

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 8

In a nitrogen-replaced glove box, 90 g (511 mmol) of benzyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 2.00 g (6.67 mmol) of BTEE, 1.23 g (3.33 mmol) of DBDT, 0.33 g (1.33 mmol) of AIBN, and 90 g of methoxypropanol were charged into a flask equipped with a stirrer, and then reacted at 60° C. for 21 hours. The polymerization rate was 99.2%, the Mw was 17,300, and the PDI was 1.45.

40.7 g (286 mmol) of butyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 29.3 g (341 mmol) of methacrylic acid (manufactured by Tokyo Chemical Industry Co., Ltd.), 0.22 g (0.67 mmol) of AIBN, and 70 g of methoxypropanol were added to the obtained solution, and then reacted at 60° C. for 24 hours. The polymerization rate was 99.6%.

After completion of the reaction, the reaction solution was poured into 5 L of heptane, the produced precipitate was suction-filtrated, and then dried, thereby obtaining 153.9 g (yield: 96%) of white powdery block copolymer F. The acid value was 118. The Mw and the PDI were measured after a carboxylic component in the block copolymer was methyl-esterified. The Mw was 25,600 and the PDI was 1.30.

+ Open protocol
+ Expand
6

Fabrication of Biofunctional Textile Composites

Check if the same lab product or an alternative is used in the 5 most similar protocols
17 α-methyltestosterone (MT, powder, >98% purity), methacrylic acid (liquid, >99% purity), ethylene glycol dimethacrylate (liquid, ˃97% purity), and ethylenediamine (liquid, 98% purity) were purchased from Tokyo Chemical Industry Co., Ltd., Japan. Azobisisobutyronitrile (12 wt% in acetone) was purchased from Sigma Aldrich, USA. Citric acid anhydrous (solid, ACS reagent, ≥99.5% purity) and ethanol (liquid, ACS grade, >99% purity) were purchased from Merck, Germany. Acetonitrile (liquid, >97% purity) was purchased from Macron and Avantor, USA. Hydrogen peroxide (30%, AR grade) was purchased from QReC New Zealand, while sodium hydroxide (pellets, AR grade, >98.6%) was purchased from Fisher, India. An SPE cartridge (C18E 500 mg/30 mL) was purchased from Welch, USA. Cotton fabric, 220 threads per inch, was supplied from a local company in Thailand.
+ Open protocol
+ Expand
7

Photoresist-Based Polymer Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Negative photoresist SU-8 3025 and positive photoresist AZ 40 XT-11D were purchased from Microchem (MA, USA) and Merck KGAs (Darmstadt, Germany) respectively. Methacrylic acid (MAA) and poly(ethylene glycol) diacrylate (PEGDA) were purchased from Tokyo Chemical Industry. MAA was filtered through an inhibitor remover column (Sigma Aldrich) prior to use. Sodium formaldehyde sulfoxylate (NaSFS) was purchased from Sigma Aldrich. 3-((((1-carboxyethyl)thio)carbonothioyl)thio)propanoic acid (CETCP) was purchased from Boron Molecular and used as received. Potassium persulfate (KPS) was purchased from Alfa Aesar and used as received.
+ Open protocol
+ Expand
8

Synthesis of Block Copolymer D

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 6

In a nitrogen-replaced glove box, 90 g (511 mmol) of benzyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 1.00 g (3.33 mmol) of BTEE, 0.62 g (1.67 mmol) of DBDT, 0.16 g (1.00 mmol) of AIBN, and 90 g of methoxypropanol were charged into a flask equipped with a stirrer, and then reacted at 60° C. for 23 hours. The polymerization rate was 99.9%, the Mw was 21,500, and the PDI was 1.46.

45 g (317 mmol) of butyl methacrylate (manufactured by Tokyo Chemical Industry Co., Ltd.), 25 g (290 mmol) of methacrylic acid (manufactured by Tokyo Chemical Industry Co., Ltd.), 0.16 g (1.00 mmol) of AIBN, and 70 g of methoxypropanol were added to the obtained solution, and then reacted at 60° C. for 19 hours. The polymerization rate was 99.7%.

After completion of the reaction, the reaction solution was poured into 5 L of heptane, the produced precipitate was suction-filtrated, and then dried, thereby obtaining 138.1 g (yield: 86%) of white powdery block copolymer D. The acid value was 102. The Mw and the PDI were measured after a carboxylic component in the block copolymer was methyl-esterified. The Mw was 43,000 and the PDI was 1.40.

+ Open protocol
+ Expand
9

Synthesis and Characterization of LiMn2O4 Cathode

Check if the same lab product or an alternative is used in the 5 most similar protocols
LiMn2O4 was purchased from FUJIFILM Wako Chemicals Co. (practical capacity of 110 mAh/g. Lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) was purchased from Kanto Chemical Co. Carbonate solvents (ethylene carbonate/diethyl carbonate = 3/7 in volume) were obtained from Kishida Chemical Co. TEMPO, thianthrene, propionyl chloride, 5-bromovaleryl chloride, methacrylic acid, and diethylene glycol monomethyl ether methacrylate (DMEM) were obtained from TCI chemicals Co. Other reagents and solvents were purchased from Kanto Chemical Co., TCI chemicals Co., FUJIFILM Wako Chemicals Co., or Sigma-Aldrich. All compounds were used as received unless noted otherwise.
+ Open protocol
+ Expand
10

Polymer Substrate Surface Functionalization

Check if the same lab product or an alternative is used in the 5 most similar protocols
All monomers
were used as received including isobornyl acrylate (IBOA, Sigma-Aldrich),
isobornyl methacrylate (VWR), and styrene (Acros Organics). The AB–L
complex, tri-n-butylborane 3-methoxypropylamine,
was donated from Callory LLC (Pittsburgh, PA) and stored in a glovebox.
All other reagents, including isophorone diisocyanate (IPDI, 98%,
Sigma-Aldrich), methacrylic acid (TCI Chemicals), polyhedral oligomeric
silsesquioxane with eight acrylopropyl groups (90%, Hybrid Plastics),
and Super P carbon black (99+%, Alfa Aesar), were used as received.
All polymer substrates were ordered from McMaster-Carr and cut into
10.2 × 2.5 × 0.3 cm (4 × 1 × 1/8 inch) specimens
from original bars of 38 × 1 × 1/8 inch. The polymer substrates
include polypropylene (part number: 8782K11), polycarbonate (part
number: 1749K119), high-density polyethylene (part number: 8671K11),
polytetrafluoroethylene (part number: 8735K12), nylon 66 (part number:
8733K11), polyvinylchloride (part number: 8740K11), and polymethylmethacrylate
(part number: 1227T119).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.