The largest database of trusted experimental protocols

Y1 20

Manufactured by Shin-Etsu Chemical

The Y1=20 is a laboratory equipment product developed by Shin-Etsu Chemical. It is designed to perform specific functions in a laboratory setting. The core function of the Y1=20 is to [insert concise, factual, and unbiased description of the product's core function, without extrapolation or interpretation].

Automatically generated - may contain errors

3 protocols using y1 20

1

Synthesis of Silicone-Based Resin 6

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 6

Synthesis of Resin 6

A 3-L flask equipped with a stirrer, thermometer, nitrogen purge line and reflux condenser was charged with 39.2 g (0.10 mol) of Compound (S-1), 26.5 g (0.10 mol) of Compound (S-2), 27.1 g (0.05 mol) of Compound (S-3c), 9.3 g (0.05 mol) of Compound (S-4), and 86.0 g (0.20 mol) of Compound (S-7), further with 2,000 g of toluene, and heated at 70° C. Thereafter, 1.0 g of a toluene solution of chloroplatinic acid (platinum concentration 0.5 wt %) was added, and 58.2 g (0.30 mol) of Compound (S-5) and 317.0 g (0.20 mol) of Compound (S-6) wherein y1=20 (Shin-Etsu Chemical Co., Ltd.) were added dropwise over 1 hour. The molar ratio of the total amount of hydrosilyl groups to the total amount of alkenyl groups was 1/1. At the end of dropwise addition, the reaction solution was heated at 100° C. and aged for 6 hours. Toluene was distilled off in vacuum from the reaction solution, yielding Resin 6. On 1H—NMR and 29Si—NMR spectroscopy (Bruker Corp.), Resin 6 was identified to contain recurring units having formulae (a1) to (a5) and (b1) to (b5). On GPC analysis, it was confirmed that the peaks assigned to the reactants had disappeared, proving that a polymer corresponding to the charge ratio was synthesized. Resin 6 had a Mw of 44,000 and a silicone content of 56.3 wt %.

+ Open protocol
+ Expand
2

Synthesis of Resin 4 via Hydrosilylation

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 4

Synthesis of Resin 4

A 3-L flask equipped with a stirrer, thermometer, nitrogen purge line and reflux condenser was charged with 39.2 g (0.10 mol) of Compound (S-1), 26.5 g (0.10 mol) of Compound (S-2), 32.5 g (0.05 mol) of Compound (S-3a), 9.3 g (0.05 mol) of Compound (S-4), and 86.0 g (0.20 mol) of Compound (S-7), further with 2,000 g of toluene, and heated at 70° C. Thereafter, 1.0 g of a toluene solution of chloroplatinic acid (platinum concentration 0.5 wt %) was added, and 58.2 g (0.30 mol) of Compound (S-5) and 317.0 g (0.20 mol) of Compound (S-6) wherein y1=20 (Shin-Etsu Chemical Co., Ltd.) were added dropwise over 1 hour. The molar ratio of the total amount of hydrosilyl groups to the total amount of alkenyl groups was 1/1. At the end of dropwise addition, the reaction solution was heated at 100° C. and aged for 6 hours. Toluene was distilled off in vacuum from the reaction solution, yielding Resin 4. On 1H—NMR and 29Si—NMR spectroscopy (Bruker Corp.), Resin 4 was identified to contain recurring units having formulae (a1) to (a5) and (b1) to (b5). On GPC analysis, it was confirmed that the peaks assigned to the reactants had disappeared, proving that a polymer corresponding to the charge ratio was synthesized. Resin 4 had a Mw of 43,000 and a silicone content of 55.7 wt %.

+ Open protocol
+ Expand
3

Synthesis of Resin 5 Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 5

Synthesis of Resin 5

A 3-L flask equipped with a stirrer, thermometer, nitrogen purge line and reflux condenser was charged with 39.2 g (0.10 mol) of Compound (S-1), 26.5 g (0.10 mol) of Compound (S-2), 26.6 g (0.05 mol) of Compound (S-3b), 9.3 g (0.05 mol) of Compound (S-4), and 86.0 g (0.20 mol) of Compound (S-7), further with 2,000 g of toluene, and heated at 70° C. Thereafter, 1.0 g of a toluene solution of chloroplatinic acid (platinum concentration 0.5 wt %) was added, and 58.2 g (0.30 mol) of Compound (S-5) and 317.0 g (0.20 mol) of Compound (S-6) wherein y1=20 (Shin-Etsu Chemical Co., Ltd.) were added dropwise over 1 hour. The molar ratio of the total amount of hydrosilyl groups to the total amount of alkenyl groups was 1/1. At the end of dropwise addition, the reaction solution was heated at 100° C. and aged for 6 hours. Toluene was distilled off in vacuum from the reaction solution, yielding Resin 5. On 1H—NMR and 29Si—NMR spectroscopy (Bruker Corp.), Resin 5 was identified to contain recurring units having formulae (a1) to (a5) and (b1) to (b5). On GPC analysis, it was confirmed that the peaks assigned to the reactants had disappeared, proving that a polymer corresponding to the charge ratio was synthesized. Resin 5 had a Mw of 45,000 and a silicone content of 56.3 wt %.

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!