Osr6195

Manufactured by Beckman Coulter
Sourced in United States

The OSR6195 is a clinical chemistry analyzer designed for the quantitative determination of various analytes in human body fluids. It is capable of performing a wide range of tests, including those for biochemistry, immunochemistry, and therapeutic drug monitoring. The OSR6195 is a compact and automated system that offers reliable and efficient laboratory testing services.

Automatically generated - may contain errors

3 protocols using osr6195

1

Lipid Profiling Using Beckman Coulter Kits

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lipids were analysed with the Beckman Coulter OSR61118 kit, total cholesterol with the OSR6216 kit, and HDL cholesterol with OSR6195 (Beckman Coulter, Brea, CA, USA) according to the manufacturer’s instructions. Chromophore reactions yield a blue color complex, which can be measured bichromatically at 650 nm with OSR61118 and OSR6195 kits, and OSR6216 kit reactions yielded red quinoneimine dye, measured spectrophotometrically at 540/600 nm as an increase in absorbance, on an Infinite 200 plate reader (Tecan company, Hamburg, Germany); each kit had a coefficient of variation of up to 5%. LDL was estimated from measured parameters by the method described in Friedwald et al. [29 (link)] and Oršolić et al. [30 (link)].
+ Open protocol
+ Expand
2

Serum Lipid Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body weight was measured at the end of the special diet, before the mice were euthanized at the beginning of an experiment. Serum was obtained through a cardiac puncture after 24 h of starvation, centrifuged at 12,500 rpm at 4 °C, and frozen at −80 °C until measured. Total cholesterol (Beckman Coulter, OSR6116, Brea, CA, USA), triglycerides (Beckman Coulter, OSR60118), HDL (Beckman Coulter, OSR6195), and LDL (Beckman Coulter, OSR6196) were measured with an AU chemistry analyzer (Beckman Coulter, AU480) according to the protocol of the manufacturer.
+ Open protocol
+ Expand
3

Lipid Profiling Protocol with Beckman Coulter

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lipids were analysed with the Beckman Coulter OSR61118 kit, total cholesterol with the OSR6216 kit, and HDL cholesterol with OSR6195 (Beckman Coulter, Brea, CA, USA) according to manufacturer instructions. Chromophore reactions were analysed on a Tecan Infinite 200 plate reader (Tecan Group Ltd., Männedorf, Switzerland) at wavelengths recommended in kit instructions for each parameter with the coefficient of variation of up to 5 %. LDL cholesterol concentrations were calculated using the Friedewald equation (13 (link), 14 (link)):
LDL-C=total cholesterol-HDL-C-[total tryglicerides/5]
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!