The largest database of trusted experimental protocols

Ge discovery mi pet ct scanner

Manufactured by GE Healthcare
Sourced in United States

The GE Discovery MI PET/CT scanner is a medical imaging device that combines positron emission tomography (PET) and computed tomography (CT) technologies. It is designed to produce high-quality images for the diagnosis and management of various medical conditions.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using ge discovery mi pet ct scanner

1

Porcine Cranial CT Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pigs were CT scanned using a GE Discovery MI PET/CT scanner (GE Healthcare, Waukesha, USA). They were scanned in the rostral caudal direction with initial alignment of the pig performed by a localizer. Subsequent CT during freezing was performed every 30 s using a 120 kVp (peak kilovoltage) and 300 mA (milliampere) current in a helical trajectory covering the animal’s skull. To avoid metal artefacts from the probe and other metal objects in the field of view, a metal artefact reconstruction (MAR) with a slice thickness of 0.625 mm was made. Final images were in-plane reconstructed in 512 × 512 matrices in a 50 cm field of view.
+ Open protocol
+ Expand
2

Cerebral Blood Flow Dynamics in MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Anonymised data from sixteen subjects enrolled in a clinical study were included in the present work. Eight subjects were healthy controls (mean age 38.6), and eight subjects were diagnosed with multiple sclerosis (MS) (mean age 43.1). MS patients' data were included due to their scans being available from a clinical parent study involving the investigation of the effect of acetazolamide on CBF in MS patients. 15O–water PET data with accompanying blood measures are rare and so all data from this other study were included to maximise the amount of data available. All subjects gave their informed consent before inclusion, and the study was approved by the medical ethics review board in Uppsala (2014/453).
Each subject underwent two dynamic PET scans both starting simultaneously with a controlled bolus injection of 5 MBq/kg of 15O–water (10 ml at 1 ml/s followed by a 30-ml saline flush at 2 ml/s) on a GE Discovery MI PET/CT scanner (GE Healthcare, Waukesha) [29 (link)]. Approximately 10 min before the second scan, the subjects were administered acetazolamide (9 mg/kg up to 1 g). The pharmacological manipulation was not of interest to the current study—all scans were included. The time between scan starts was approximately 20 min to allow for radioactive decay.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!