7900ht fast real time pcr system sequencer detector

Manufactured by Thermo Fisher Scientific

The 7900HT Fast Real-Time PCR System is a high-performance quantitative PCR (qPCR) instrument designed for fast, accurate, and sensitive detection and quantification of nucleic acids. It features a high-resolution CCD detector, a fast thermal cycler, and flexible software for a wide range of real-time PCR applications.

Automatically generated - may contain errors

4 protocols using 7900ht fast real time pcr system sequencer detector

1

Quantitative PCR Analysis of LSK Cell Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
BM LSKs were purified from femurs and tibiae. Staining was performance as described above. Total RNA was prepared with RNA Extraction RNeasy Plus Mini- or Micro-kit (Qiagen). RNA was reverse-transcribed with High-Capacity cDNA Reverse Transcription reagents kit (Applied Biosystems) according to the manufacturer's protocol. Real-time quantitative PCR (SYBR-green, Applied Biosystems) assays were performed with an Applied Biosystems 7900HT Fast Real-Time PCR System sequencer detector. Expression was normalized to Hprt (F-5′-CCTAAGATGAGCGCAAGTTGAA-3′, R-5′-CCACAGGACTAGAACACCTGCTAA-3′) and 36b4 (F-5′-ACTGGTCTAGGACCCGAGAAG-3′, R-5′-TCCCACCTTGTCTCCAGTCT-3′) expression. The primer sequences for Glg-1 were: F-5′-CAAGATGACGGCCATCATTTT-3′, R-5′-TTCCCCAAGACGAATGCTGC-3′; for p18: F-5′-TTATGAAGCACACAGCCTGCAATGT-3′, R-5′-ACGGACAGCCAACCAACTAACGG-3′; for p21: F-5′-TGTCTTGCACTCTGGTGTCTGAGC-3′, R-5′-TCTTGCAGAAGACCAATCTGCG-3′; for p57: F-5′-GCGCAAACGTCTGAGATGAG-3′, R-5′-AGAGTTCTTCCATCGTCCGCT-3′; for Tgfb1: F-5′-CCGAAGCGGACTACTAT-3′; R-5′-GTAACGCCAGGAATTGT-3′.
+ Open protocol
+ Expand
2

Quantitative Transcriptional Profiling of Progenitor Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total RNA was prepared from FACS sorted progenitor populations with the RNA Extraction RNeasy Plus Mini-kit (QIAGEN) and RNA was reverse-transcribed with the HighCapacity cDNA Reverse Transcription kit (Applied Biosystems; Carlsbad, CA) according to the manufacturer’s protocol. Real-time quantitative PCR (SYBR-green, Applied Biosystems) assays were performed with an Applied Biosystems 7900HT Fast Real-Time PCR System sequencer detector. Expression was normalized to the expression of the Actb housekeeping gene. ThPOK: F 5’-ACCCAACGGCTGAAAGGA-3’, R 5’-GCTGCTGTGGTCTGGCAAT-3’. Irf8: F 5’-GACACACACCATTCAGCTTTC-3’, R: 5’-CATCCGGCCCATACAACTTA-3’. Zeb2: F 5’-CGCCACGAGAAGAATGAAGA-3’, R 5’-GGTTAGCATTTGGTGCTGATC-3’, Cebpe: F 5’-GCAGCCACTTGAGTTCTCAGG-3’, R 5’-GATGTAGGCGGAGAGGTCGAT-3’, Ezh2 (ref transcript): F 5’-TGTTACCAGCATCTGCCAC-3’, R 5’-AACTCCTTAGCTCCCTCCTT-3’, Ezh2 (ASE): F 5’-GTGTTACCAGCATCTGGAGG-3’, R 5’-GTCTGCTACTGTTATTCGGAAGT-3’, Hmga1 (ref. transcript) F 5’-TGGTCGGGAGTCAGAAAGA-3’. R 5’-CTTCTCCAGTTTCTTGGGTCTG-3’. Hmga1ASE: F 5’-CAAGCAGCCTCCGAAAGA-3’. R 5’-TTCCTCCCTGGAGCTGT-3’. For the rest we used Taqman qPCR assays (Applied Biosystem). Runx1-Mm01213405_m1, NKg7-Mm00452524_g1, Pde4d-Mm00456879_m1, Ddx3x-Mm04207948_gH, Cd63-Mm01966817_g1 Srsf5-Mm00833629_g1and used Actb: Mm01205647_g1 as normalizer.
+ Open protocol
+ Expand
3

Quantitative Real-Time PCR Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total RNA from sorted macrophages was prepared with RNA Extraction RNeasy Plus Micro-kit (QIAGEN). For whole tissue RNA extraction, TRIzol (Sigma-Aldrich) extraction method was used. RNA was reverse-transcribed with High-Capacity cDNA Reverse Transcription reagents kit (Applied Biosystems) according to the manufacturer’s protocol. Real-time quantitative PCR (SYBRGreen; Applied Biosystems) assays were performed with an Applied Biosystems 7900HT Fast Real-Time PCR System sequencer detector. Expression was normalized to 36b4 expression. Primer sequences are listed in the Table S2.
+ Open protocol
+ Expand
4

RNA Extraction and Real-Time qPCR

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total RNA was prepared with RNA Extraction RNeasy Plus Mini- or Micro-kit (QIAGEN) for isolation from macrophages or with TRIzol (Sigma) for total tissue RNA. RNA was reverse transcribed with High-Capacity cDNA Reverse Transcription kit (Applied Biosystems) according to the manufacturer’s protocol. Real-time quantitative PCR (SYBR-green; Applied Biosystems) assays were performed with an Applied Biosystems 7900HT Fast Real-Time PCR System sequencer detector. Expression was normalized to Hprt and/or 36b4 expression. Primer sequences are listed in Table S3.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!