The largest database of trusted experimental protocols

Agilent 6230 accurate mass tof ms mass spectrometer

Manufactured by Agilent Technologies

The Agilent 6230 Accurate-Mass TOF-MS is a high-performance time-of-flight mass spectrometer designed for accurate mass measurements. The instrument utilizes an orthogonal acceleration time-of-flight mass analyzer to provide high mass resolution and mass accuracy.

Automatically generated - may contain errors

2 protocols using agilent 6230 accurate mass tof ms mass spectrometer

1

Purification and Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents and solvents were
purchased from Sigma-Aldrich Co. LLC (Merck KGaA, Darmstadt, Germany)
unless indicated otherwise. Water was purified by a Millipore purification
system (Merck KGaA). NMR spectra were recorded on a Jeol ECA-500 (Jeol
Ltd., Tokyo, Japan). Solvent mixtures for chromatography are reported
as volume/volume (v/v) ratios. Reverse phase high performance liquid
chromatography (HPLC) purifications were performed on a CombiFlash
EZ Prep (Teledyne Isco, Inc.) with a RediSep Prep C18 column (20 ×
150 mm2) with Phase A/Phase B gradients [Phase A: H2O with 0.1% formic acid; Phase B: MeOH with 0.1% formic acid]
at a flow rate of 19 mL/min. The HPLC was equipped with a UV–vis
detector and an evaporative light scattering detector (ELSD). High-resolution
mass (HRMS) analyses were performed by electrospray ionization–time
of flight (ESI-TOF) on an Agilent 6230 Accurate-Mass TOF-MS mass spectrometer.
+ Open protocol
+ Expand
2

HPLC Purification and Mass Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Solvent mixtures for chromatography are reported as volume/volume (v/v) ratios. HPLC analyses were performed with an Eclipse Plus C8 analytical column with gradients based on Phase A and Phase B (where Phase A: H2O with 0.1% formic acid; Phase B: MeOH with 0.1% formic acid). For purification purposes, Zorbax SB-C18 semi-preparative column was used with gradients based on Phase A and Phase B gradients (where Phase A: H2O with 0.1% formic acid; Phase B: MeOH with 0.1% formic acid). Agilent 6230 Accurate-Mass TOFMS mass spectrometer was used to obtain electrospray ionization-time-of-flight (ESI-TOF) mass spectra. A Varian 380-LC detector was used to record ELSD chromatograms.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.