The largest database of trusted experimental protocols

2 protocols using depletion c2f2

1

Multicolor Flow Cytometry of Immune Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fluorophore- or biotin-conjugated antibodies specific for mouse cell-surface antigens and cytokines were as follows: anti-B220 (RA3-6B2, BioLegend), anti-CD4 (GK1.5, BioLegend), anti-CD8a (53-6.7, BioLegend), anti-CD11b (M1/70, BioLegend), anti-Gr1 (RB6-8C5, BioLegend), anti-CD25 (3C7, BioLegend), anti-Foxp3 (MF14, eBioscience), anti-TER119 (TER-119, BioLegend), anti-CD71 (R17 217.1.3, BioXCell for depletion; C2F2, BD biosciences for FACS analysis), anti-CD45 (I3/2.3, BioLegend), anti-CD90.1 (16-10A1, BioLegend), anti-Gzmb (GL1, BioLegend), anti-IFN-γ (XMG1.2, BioLegend). anti-CXCR5 (L138D7, BioLegend), anti-mouse/human CD44 (IM7, BioLegend), anti-human/mouse Bcl-6 (7D1, BioLegend), anti-T-bet (4B10, BioLegend), anti-mouse Ki-67 (16A8, BioLegend), anti-mouse TNF-α (MP6-XT22, BD). For human studies, the following fluorophore- or biotin-conjugated antibodies specific for cell surface markers or cytokines were used: anti-CD3 (UCHT, BioLegend), anti-CD8 (PRA-T8, BioLegend), anti-CD45 (2D1, BioLegend), anti-CD71 (CY1G4, BioLegend), anti-CD235a (HI264, BioLegend). ROS production was measured by labelling with 2′,7′ –dichlorofluorescin diacetate using the ROS detection kit (S0033, Beyotime).
+ Open protocol
+ Expand
2

Multicolor Flow Cytometry of Immune Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fluorophore- or biotin-conjugated antibodies specific for mouse cell-surface antigens and cytokines were as follows: anti-B220 (RA3-6B2, BioLegend), anti-CD4 (GK1.5, BioLegend), anti-CD8a (53-6.7, BioLegend), anti-CD11b (M1/70, BioLegend), anti-Gr1 (RB6-8C5, BioLegend), anti-CD25 (3C7, BioLegend), anti-Foxp3 (MF14, eBioscience), anti-TER119 (TER-119, BioLegend), anti-CD71 (R17 217.1.3, BioXCell for depletion; C2F2, BD biosciences for FACS analysis), anti-CD45 (I3/2.3, BioLegend), anti-CD90.1 (16-10A1, BioLegend), anti-Gzmb (GL1, BioLegend), anti-IFN-γ (XMG1.2, BioLegend). anti-CXCR5 (L138D7, BioLegend), anti-mouse/human CD44 (IM7, BioLegend), anti-human/mouse Bcl-6 (7D1, BioLegend), anti-T-bet (4B10, BioLegend), anti-mouse Ki-67 (16A8, BioLegend), anti-mouse TNF-α (MP6-XT22, BD). For human studies, the following fluorophore- or biotin-conjugated antibodies specific for cell surface markers or cytokines were used: anti-CD3 (UCHT, BioLegend), anti-CD8 (PRA-T8, BioLegend), anti-CD45 (2D1, BioLegend), anti-CD71 (CY1G4, BioLegend), anti-CD235a (HI264, BioLegend). ROS production was measured by labelling with 2′,7′ –dichlorofluorescin diacetate using the ROS detection kit (S0033, Beyotime).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!