The largest database of trusted experimental protocols

Pl gpc50 agilent 1260

Manufactured by Agilent Technologies

The PL-GPC50/Agilent 1260 is a gel permeation chromatography (GPC) system designed for the analysis of polymer molecular weight and molecular weight distribution. It features an Agilent 1260 Infinity II LC system with a refractive index (RI) detector.

Automatically generated - may contain errors

2 protocols using pl gpc50 agilent 1260

1

Characterization of Polymeric Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
The morphologies of MAL-PEG-b-PLL/PBA, PMs@NaF and PMs@NaF-SAP were observed using transmission electron micrographs (TEM, JEM-100SX, Japan). The particle size and zeta potential of polymers were measured using dynamic light scattering (DLS, Zetasizer Nano ZS90, Malvern Instruments, Malvern, UK). The concentrations of each polymer were measured by lyophilization. The molecular weight and polydispersity index (PDI) of the samples were determined by Gel Permeation Chromatography (GPC, Agilent PL-GPC50/Agilent 1260). The FT-IR spectra of the samples were recorded using a fourier transform infrared spectrometer (FTIR spectrometer, NICOLET 5700) to confirm the successful conjugation between PMs@NaF and SAP. After dissolving in DMSO-d6, the 1H NMR spectra of MAL-PEG-b-PLL/PBA and PMs were recorded using a Bruker Avance spectrometer (Bruker AV II-400 MHz).
+ Open protocol
+ Expand
2

Gadolinium-Labeled Theranostic Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
1,1-Carbonyldiimidazole (CDI), branched polyethylenimine (PEI, Mw = 800 Da), and folic acid were purchased from Sigma-Aldrich. GdCl3·6H2O was purchased from Tokyo Chemical Industry. N3-PEG2000-NH2 was obtained from Xiamen Sinopeg Biotech CO., Ltd. Cyclodextrin underwent recrystallization three times in water, and was stored in a vacuum drying oven at 60 °C before use. DBCO-PEG2000-NH2 was purchased from Xi'an Confluore Biological Technology Co., Ltd. Ad-PEG2000-PLL(DTPA-Gd)-N3 and DBCO-PEG2000-FA were synthesized in our lab.30 All the other reagents were obtained from the domestic suppliers.
1H NMR spectra were obtained using a Varian NMR spectrometer at 400 MHz. Gel permeation chromatography (GPC) measurements were carried out using an Agilent PL-GPC50/Agilent 1260, 0.15 M NaNO3 water solution was used as an eluent with a flow rate of 1 mL min−1. The Gd concentrations of the samples were detected via an inductively coupled plasma optical emission spectrometer (ICP-OES, Agilent 720ES). The in vitro T1-weighted data were obtained via a 0.5T NMR-analyzer, while the in vivo T1-weighted MR images were acquired on a 4.7T scanner (Bruker).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!