The largest database of trusted experimental protocols

Hydrochloric acid 1 n

Manufactured by Avantor
Sourced in United States

Hydrochloric acid (1 N) is a laboratory reagent that is widely used in various scientific applications. It is a clear, colorless solution of hydrogen chloride in water, with a concentration of 1 Normal (N). This product is commonly used in titrations, pH adjustments, and other analytical procedures where a standard strength of hydrochloric acid is required.

Automatically generated - may contain errors

2 protocols using hydrochloric acid 1 n

1

Formulation and Characterization of Lipid-Based Drug Delivery Systems

Check if the same lab product or an alternative is used in the 5 most similar protocols
Capmul MCM (HLB 4.7) was obtained as a gift from Abitec Corporation (Columbus, OH). The composition of Capmul MCM is approximately 60% of medium-chain monoglycerides and 40% of diglycerides, derived from caprylic acid (83%) and capric acid (17%). Danazol was donated by Sanofi-Aventis Pharmaceutics (Bridgewater, NJ). Caprylic acid (HLB 1), indomethacin, haloperidol, hydrochloric acid (1 N), potassium chloride, potassium phosphate monobasic, sodium hydroxide, sodium acetate, acetic acid, and polyethylene glycol (PEG) 400 were purchased from VWR (Solon, OH). Cremophor RH40 (HLB 14–16) was supplied by BASF Corporation (Tarrytown, NJ). All chemicals and solvents were of analytical purity or high performance liquid chromatography (HPLC) grade and used as received with no further treatment.
+ Open protocol
+ Expand
2

Preparation of AAA Stock Solution

Check if the same lab product or an alternative is used in the 5 most similar protocols
A 120 mg amount of AAA (Lot: BVBG0603V; Sigma-Aldrich Corp., St. Louis, MO, USA) was dissolved in 1 mL hydrochloric acid [1 N] (VWR, Radnor, PA, USA). This AAA stock was diluted to an 80 mM solution using 0.9% sterile normal saline solution and was brought to a pH of 7.4. The final solution was passed through a disposable Millex-GP syringe filter unit with a pore size of 0.22 lm (Batch, MKBL8989; Sigma-Aldrich Corp.) to remove any potential particulates. Solutions were made immediately before use and all solutions remained at room temperature until time of injection.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.