The largest database of trusted experimental protocols

Fenpropathrin

Manufactured by LGC
Sourced in Germany

Fenpropathrin is a synthetic pyrethroid insecticide used in laboratory research and testing. It acts as a neurotoxin, disrupting the normal function of the nervous system in target organisms. The product's core function is to provide a chemical tool for evaluating the effects of pyrethroid insecticides in controlled experimental settings.

Automatically generated - may contain errors

4 protocols using fenpropathrin

1

Pesticide Residue Analysis in Rape Flowers

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Milli-Q ultrapure water system manufactured by Millipore (Milford, UT, USA) was used throughout experiments to provide the HPLC-grade water that was employed during analysis and to hydrate the rape flower samples. Ultragradient HPLC-grade acetonitrile and methanol were obtained from Tedia (Shanghai, China). Formic acid, acetic acid, anhydrous magnesium sulfate (MgSO4), and sodium acetate (NaOAc) were supplied by Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). PSA (primary and secondary amine-bonded silica), C18 (octadecyl-bonded silica) and GCB (graphitized carbon black) were purchased from Agilent Technologies (Santa Clara, CA, USA).
Reference standards of imidacloprid (purity, 98%), thiamethoxam (purity, 95%), acetamiprid (purity, 95%), fenpropathrin (purity, 98.5%), chlorpyrifos (purity, 98%), carbendazim (purity, 95%), prochloraz (purity, 98%) and pyrimethanil (purity, 95%) were obtained from Dr. Ehrenstorfer GmbH (Augsburg, Germany).
Formulated pesticides of imidacloprid 10% wettable powder (WP), thiamethoxam 25% water-dispersible granules (WDG), acetamiprid 20% WP, fenpropathrin 20% emulsifiable concentrate (EC), chlorpyrifos 40% EC, carbendazim 80% WP, prochloraz 25% EC, and pyrimethanil 40% suspension concentrate (SC) were purchased from the agricultural market located in Hefei, Anhui, China.
+ Open protocol
+ Expand
2

Comprehensive Pesticide Residue Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pesticide reference standards including malathion, diazinon, profenofos, primiphos-methy, chlorpyrifos-methyl, monocrotophos, dimethoate, cypermethrin, deltamethrin, fenpropathrin, oxamyl, imidacloprid, acetamiprid, metalaxyl, difenoconazole, α-BHC, β-BHC, γ-BHC, δ-BHC, heptachlor, aldrin, heptachlor epoxide, trans-chlordane, α-endosulfan, β-endosulfan, cis-chlordane trans-nonachlor, dieldrin, P-P-DDE, endrin, cis-nonachlor, P-P-DDD, endosulfan-sulfate, P,P-DDT, and methoxychlor were purchased from Dr. Ehrenstorfer GmbH (Augsburg, Germany), with certified purity ranging from 97% to 99%. Acetonitrile, tolune, ammonia solution, sodium chloride, acetic acid, triphenylphosphate (TPP), and ethoprophos were obtained from Merck (Darmstadt, Germany), and anhydrous magnesium sulfate, Bondesil sorbents (primary and secondary amine; PSA particle size 40 μm), and graphite carbon black (GCB) from Sigma-Aldrich (St. Louis, MO, USA). All the organic solvents used were higher performance liquid chromatography (HPLC) grade.
+ Open protocol
+ Expand
3

Pesticide and Heavy Metal Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All pesticides standards including α-BHC(100 mg L−1), β-BHC (100 mg L−1), γ-BHC (100 mg L−1), δ-BHC (100 mg L−1), p,p′-DDE (100 mg L−1), o,p′-DDT (100 mg L−1), p,p′-DDT (100 mg L−1), p,p′-DDD (100 mg L−1), azoxystrobin (99.0%), carbendazim (99.0%), chlorothalonil (98.9%), chlorpyrifos (99.5%), cypermethrin (98.2%), chlorantraniliprole (98.2%), dichlorvos (99.7%), difenoconazole (99.2%), fenpropathrin (98.9%), isocarbophos (98.9%), procymidone (99.5%), prochloraz (99.2%), pyraclostrobin (98.1%), thiophanate-methyl (99.3%), tebuconazole (99.5%) and λ-cyhalothrin (93.5%) were purchased from Dr Ehrenstorfer GmbH (Augsburg, Germany). Acetonitrile (HPLC grade) were provided by Bangyi Chemical Co., Ltd. (Hangzhou, China). Anhydrous magnesium sulphate, anhydrous sodium sulphate and n-hexane were of analytical grade. Primary secondary amine (PSA) was provided by Agela Technologies.
Each single element stock solution (1000 mg L−1) of Cu, Zn, Cr, Ni, Pb, As, Cd, and Hg were purchased from National Standard Material Research Centre (Beijing, China). Guaranteed reagent nitric acid (HNO3) was provided by Fanhong Trading Co., Ltd. (Guangzhou, China).
+ Open protocol
+ Expand
4

Pyrethroid Determination in Herbal Teas

Check if the same lab product or an alternative is used in the 5 most similar protocols
Honeysuckle, chrysanthemum, wolfberry, and licorice tea leaves were purchased from the local market as the main materials. None of the studied pyrethroids were detected in the four herbal tea samples.
Unless otherwise stated, all reagents and chemicals used in this study were purchased from Xilong Chemical Co., Ltd. (Shantou, China). High-performance liquid chromatography (HPLC)-grade n-hexane was obtained from Tedia Company, Inc. (Fairfield, OH, USA). Solid phase extraction (SPE) Florisil cartridges (1000 mg, 6 mL) were acquired from Agela Technologies (Beijing, China). Fenpropathrin (99.2%), beta-cypermethrin (99.2%), lambda-cyhalothrin (99.2%), and fenvalerate (99.0%) standards were purchased from Ehrenstorfer GmbH (Augsburg, Germany). Standard stock solutions of the four pyrethroids were prepared and diluted in n-hexane, and matrix-matched standard solutions were prepared by adding appropriate amounts of stock solution to blank (pesticide-free) extracts of herbal tea and its infusion. All solutions were stored at 4 °C until use.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!