The largest database of trusted experimental protocols

Diode array detector

Manufactured by Gilson

The Diode Array Detector is a type of spectrophotometric detector used in high-performance liquid chromatography (HPLC) systems. It measures the absorbance of light by the analytes eluting from the HPLC column at multiple wavelengths simultaneously, providing detailed spectral information about the detected compounds.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using diode array detector

1

HPLC-DAD Analysis of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC-DAD for analysis was performed on Gilson GX-271 Liquid Handler with system 322 H2 Pump connected to a 171 Gilson Diode Array Detector and fraction collector. A XBridge BEH C18 XP Column (130 Å, 2.5 μm, 4.6 mm × 100 mm) with XBridge BEH C18 XP VanGuard Cartridge (130 Å, 2.5 μm, 3.9 mm × 5 mm) was used for analytical run with a flow rate of 0.8 ml/min. HPLC-grade water with 0.5% formic acid (solvent A) and HPLC-grade acetonitrile with 0.5% formic acid (solvent B) were used with the following gradients: 0 min, 20% Solvent B; 2 min, 20% Solvent B; 15 min, 95% Solvent B; 18 min, 95% Solvent B; 20 min, 20% Solvent B. Data acquisition and procession for the HPLC-DAD were controlled by TRILUTION LC V3.0.
+ Open protocol
+ Expand
2

HPLC-DAD Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC-DAD for analysis was performed on Gilson GX-271 Liquid Handler with system 322 H2 Pump connected to a 171 Gilson Diode Array Detector and fraction collector. A XBridge BEH C18 XP Column (130 Å, 2.5 μm, 4.6mm × 100mm) with XBridge BEH C18 XP VanGuard Cartridge (130 Å, 2.5 μm, 3.9mm × 5mm) was used for analytical run with a flow rate of 0.8 ml/min. HPLC-grade water with 0.5% formic acid (solvent A) and HPLC-grade acetonitrile with 0.5% formic acid (solvent B) were used with the following gradients: 0min, 20% Solvent B; 2min, 20% Solvent B; 15 min, 95% Solvent B; 18 min, 95% Solvent B; 20 min, 20% Solvent B. Data acquisition and procession for the HPLC-DAD were controlled by TRILUTION LC V3.0.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!