The largest database of trusted experimental protocols

Rapid auto

Manufactured by Rigaku

The RAPID-AUTO is a high-speed X-ray diffraction (XRD) system designed for automated powder sample analysis. It features a high-intensity X-ray source, a high-speed detector, and an automated sample handling system. The RAPID-AUTO is capable of performing rapid, high-resolution XRD measurements on a variety of powder samples.

Automatically generated - may contain errors

30 protocols using rapid auto

1

X-ray Structure Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: RAPID-AUTO (Rigaku, 1998 ▶ ); cell refinement: RAPID-AUTO; data reduction: CrystalClear (Rigaku/MSC, 2002 ▶ ); program(s) used to solve structure: SHELXS97 (Sheldrick, 2008 ▶ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▶ ); molecular graphics: DIAMOND (Brandenburg, 1999 ▶ ); software used to prepare material for publication: SHELXTL (Sheldrick, 2008 ▶ ).
+ Open protocol
+ Expand
2

Single Crystal X-Ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: RAPID-AUTO (Rigaku, 1998 ▶ ); cell refinement: RAPID-AUTO; data reduction: CrystalStructure (Rigaku/MSC, 2006 ▶ ); program(s) used to solve structure: SHELXS97 (Sheldrick, 2008 ▶ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▶ ); molecular graphics: ORTEPII (Johnson, 1976 ▶ ); software used to prepare material for publication: SHELXL97.
+ Open protocol
+ Expand
3

Single Crystal X-Ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: RAPID-AUTO (Rigaku, 2011 ▸ ); cell refinement: RAPID-AUTO; data reduction: RAPID-AUTO; program(s) used to solve structure: Il Milione (Burla et al., 2007 ▸ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▸ ); molecular graphics: CrystalStructure (Rigaku, 2011 ▸ ); software used to prepare material for publication: CrystalStructure.
+ Open protocol
+ Expand
4

Single Crystal X-ray Diffraction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: RAPID-AUTO (Rigaku, 2001 ▸ ); cell refinement: RAPID-AUTO; data reduction: RAPID-AUTO; program(s) used to solve structure: SIR92 (Altomare et al., 1994 ▸ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▸ ); molecular graphics: CrystalStructure (Rigaku, 2010 ▸ ); software used to prepare material for publication: CrystalStructure.
+ Open protocol
+ Expand
5

X-ray Crystallographic Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: RAPID-AUTO (Rigaku, 2006 ▶ ); cell refinement: RAPID-AUTO; data reduction: RAPID-AUTO; program(s) used to solve structure: SHELXS97 (Sheldrick, 2008 ▶ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▶ ); molecular graphics: locally modified version of ORTEP (Johnson, 1965 ▶ ); software used to prepare material for publication: WinGX (Farrugia, 2012 ▶ ).
+ Open protocol
+ Expand
6

Cultivation and Structural Characterization of PNBA Crystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
The single crystals of PNBA form (I), (I)·DMSO solvate, (I)·DMF-solvate, (I)·NMP-solvate and (I)·DMA-solvate were cultivated using the slow solvent evaporation method. A saturated solution (2 ml) of PNBA sealed with plastic film was placed into an oven and kept at 298.15 K. Then, crystals of PNBA form (I) and solvates with suitable sizes for single crystal X-ray diffraction were collected after several days. The single-crystal data collection was conducted at 113 K on a Rigaku Rapid II diffractometer, Mo Kα radiation (λ = 0.71073 Å). Data collection and processing were performed with Rapid-auto (Rigaku/MSC, 2004 ▸ ). Data reduction and cell refinement were performed with SHELXS-97 (Sheldrick, 2008 ▸ ) and SHELXL-97 (Sheldrick, 2015 ▸ ), respectively.
+ Open protocol
+ Expand
7

Single Crystal X-ray Diffraction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: RAPID-AUTO (Rigaku, 2001 ▸ ); cell refinement: RAPID-AUTO; data reduction: RAPID-AUTO; program(s) used to solve structure: SIR92 (Altomare et al., 1994 ▸ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▸ ); molecular graphics: CrystalStructure (Rigaku, 2010 ▸ ); software used to prepare material for publication: CrystalStructure.
+ Open protocol
+ Expand
8

Crystal Structure Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: RAPID-AUTO (Rigaku, 2009 ▸ ); cell refinement: RAPID-AUTO; data reduction: RAPID-AUTO; program(s) used to solve structure: SIR2011 (Burla et al., 2012 ▸ ); program(s) used to refine structure: SHELXL2013 (Sheldrick, 2015 ▸ ); molecular graphics: CrystalStructure (Rigaku, 2014 ▸ ); software used to prepare material for publication: CrystalStructure.
+ Open protocol
+ Expand
9

Single Crystal X-Ray Diffraction of POM-AMB-acy

Check if the same lab product or an alternative is used in the 5 most similar protocols
A red single crystal of POM-AMB-acy with three dimensions of 0.40 mm × 0.50 mm × 0.50 mm was selected for diffraction analysis. The data collection was performed on a Rigaku RAXIS-SPIDER IP diffractometer at 50 kV and 20 mA, using graphite monochromatized Mo Kα radiation (λ = 0.71073 Å) at 94(2) K. Data collection, data reduction, cell refinement, and experimental absorption correction were performed with the software package of Rigaku RAPID AUTO (Rigaku, 1998, Ver2.30). Structures were solved by direct methods and refined against F2 by full matrix least squares. All non-hydrogen atoms, except disordered atoms, were refined anisotropically. Hydrogen atoms were generated geometrically. All calculations were performed using the SHELXS-97 program package.
+ Open protocol
+ Expand
10

Single-Crystal Diffraction at 90K

Check if the same lab product or an alternative is used in the 5 most similar protocols
Single-crystal diffraction measurements at 90 K for crystals of A and B, immersed in a paratone N-oil and mounted on Micro Mounts holder, were conducted using Rigaku R-axis RAPID diffractometer. Collected data were processed by using RAPID AUTO (Rigaku). Crystal structures were solved by a direct method with SIR2011 (ref. 12 (link)) for A and SHELXS97 (ref. 13 (link)) for B using CrystalStructure 4.2 crystallographic software package14 with the exception of refinement, which was performed using SHELXL-2018/3 (ref. 15 ) by a full-matrix least-squares technique. For disordered parts, isotropic refinements were performed. The disordered model was fixed with some restraints and constraints. Molecular graphics were prepared using Mercury 3.8 software.16 (link)
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!