3 protocols using resomer rg 504

1

Polymer Nanoparticle Synthesis and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following chemicals were obtained from commercial suppliers and used as received: the polymer poly(d,l-lactic-co-glycolic acid) 50 : 50 (PLGA; MW 38 000–54 000 Da, Tg 46–50 °C), under the commercial name of Resomer® RG 504 was purchased from Boehringer Ingelheim (Ingelheim, Germany) and Evonik Industries (Evonik Röhm GmbH, Germany). Sodium cholate, chloroauric acid (HAuCl4·3H2O), sodium citrate tribasic dehydrate ≥99.0% (Na3C6H5O7·2H2O), PVA (polyvinyl alcohol) MW 85 000–124 000 Da, 97–99% hydrolyzed, taurocholic acid sodium salt hydrate ≥95% (TLC), ethyl acetate ACS reagent, dodecanethiol, phosphotungstic acid hydrate as a contrast agent for microscopy and fluorescent molecule pyrene ≥99.0% were purchased from Sigma Aldrich (St Louis, MO, USA).
+ Open protocol
+ Expand
2

Biodegradable PLGA Polymer Formulations

Check if the same lab product or an alternative is used in the 5 most similar protocols
Poly(D,L-lactide-co-glycolide) (PLGA) 50:50 Resomer ® RG 504 (Mw 40-50 kDa; ester terminated), poly(D,L-lactide) Resomer ® R 202 H (Mw 10-18 kDa; acid terminated) and poly(D,L-lactide)
Resomer ® R 202 S (Mw 10-18 kDa; ester terminated) were supplied by Boehringer Ingelheim (Ingelheim, Germany). Prior to use, the polymer was dried under vacuum for 24 h to eliminate traces of moisture. Ketoprofen (KET) was kindly provided by Bidachem SpA (Bergamo, Italy), while methylene chloride (CH2Cl2) was supplied by Sigma-Aldrich (Milan, Italy).
+ Open protocol
+ Expand
3

Encapsulation of Uncaria tomentosa Extract

Check if the same lab product or an alternative is used in the 5 most similar protocols
Uncaria tomentosa dried extract (4.5% of total pentacyclic oxindole alkaloids) was kindly donated by Herbarium Laboratório Botânico (PR, Brazil). Poly-e-caprolactone (PCL; Mw 70,000-90,0000 g/mol), polyvinyl alcohol (PVA; Mw 31,000-50,000 g/mol, 87-89% hydrolyzed) and cellulose dialysis membranes (flexible tube type, 33 mm, 14 kDa MWCO) were obtained from Sigma-Aldrich (MO, USA). Poly-d,l-lactide-coglycolide (PLGA), with 50:50 D,L-lactide:glycolide molar ratio and intrinsic viscosity of 0.45-0.60 dl/g (Resomer® RG 504), was purchased from Boehringer Ingelheim (RP, Germany) and poloxamer 188 (Lutrol® F68, Mw 7680-9510 Da) from BSAF (RP, Germany). Methylene chloride, ethyl acetate, acetone and ethanol were acquired from Tedia Brazil (RJ, Brazil).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!