The largest database of trusted experimental protocols

Sense cardiac surface coil

Manufactured by Philips

The SENSE cardiac surface coil is a medical imaging device used in Magnetic Resonance Imaging (MRI) procedures. It is designed to capture high-quality images of the heart and surrounding structures. The coil is placed on the patient's chest during the MRI scan to enhance the signal-to-noise ratio and improve the overall image quality of the cardiac region.

Automatically generated - may contain errors

2 protocols using sense cardiac surface coil

1

Multiparametric MRI Prostate Cancer Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
A 3.0 Tesla (3T) MRI (Achieva, Philips Medical Systems, Best, Netherlands) was used to acquire all images. A previously published prostate mpMRI protocol was followed to obtain T2 weighted imaging (T2WI) with apparent diffusion coefficient (ADC) mapping, diffusion weighted imaging (DWI) with high b value (b = 2000 s/mm2), and dynamic contrast-enhanced (DCE) sequences. A 16-channel surface-array coil (SENSE cardiac surface coil, Philips Medical Systems, Best, the Netherlands) positioned over the pelvis and an endorectal coil (BPX-30, BAYER, Medrad, Pittsburgh, Pennsylvania) were also utilized. A single genitourinary radiologist with 9 years of experience interpreting prostate mpMRI evaluated all images.
All patients included in this analysis underwent standard-of-care, non-targeted transrectal ultrasound (TRUS) guided systematic 12-core biopsy in an outpatient setting. A single, genitourinary pathologist reviewed all core specimens. Clinically significant disease was defined as having any Gleason ≥ 7 (3 + 4) on histologic evaluation, and the highest histologic grade was recorded for each patient’s biopsy results. For patients who did not undergo systemic biopsy at National Institutes of Health, tissue from outside institutions was internally reviewed. Verified outside pathology reports were considered when specimens were not available.
+ Open protocol
+ Expand
2

Multiparametric MRI Prostate Cancer Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
All images were acquired at 3.0 Tesla scanner (Achieva 3.0T-TX, Philips Healthcare, Best, Netherlands). Patients were scanned using combination of a 16-channel surface-array coil (SENSE cardiac surface coil, Philips Medical Systems, Best, the Netherlands) and an endorectal coil (ERC) (BPX-30, BAYER, Medrad, Pittsburgh, Pennsylvania) or a 32-channel cardiac SENSE coil (Invivo, Gainesville, Florida). A T2-weigh-ted image (T2WI), diffusion-weighted image (DWI) with high b value (b = 2000 s/mm2 with ERC, and b = 1500 s/mm2 without ERC) with apparent diffusion coefficient (ADC) mapping, and dynamic contrast-enhanced (DCE) sequences were obtained per PI-RADSv2 recommendations [4 (link)]. Full mpMRI parameters are provided in Supplemental Table 1. A single, experienced genitourinary radiologist with 10 years of experience interpreted all images prospectively using PI-RADSv2 guidelines [8 (link)]. Lesion diameters were prospectively recorded on axial T2 W MRI. Prostate volumes were estimated on axial T2 W MRI using a commercially available automated planimetric software, which has been previously validated [9 (link)]. Relative lesion diameter was defined as the ratio of lesion diameter to prostate volume.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!