The largest database of trusted experimental protocols

2 protocols using cd5 alexafluor 700

1

Multiparameter Flow Cytometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Antibodies obtained from BD Biosciences (San Jose, CA) include mouse anti-human CD19 peridinin-chlorophyll protein, CD5 alexafluor 700, CD20 phycoerythrin cyanine 7, CD14 allophycocyanin, CD3 phycoerythrin cyanine fluorescent 594, STAT6 tyrosine 641 phycoerythrin, and pAKTS473 phycoerythrin cyanine fluorescent 594. SYKY525/526 phycoerythrin and ERKY204 allophycocyanin were obtained from Cell Signaling Technologies (Danvers, MA). Goat anti-human IgD (Bethyl Laboratories, Montgomery, TX), donkey anti-human IgM (Jackson Immunoresearch, (West Grove, PA) and recombinant human IL-4 (R&D Systems, Minneapolis, MN) were used for whole blood stimulations. Phosphate buffered saline (PBS), bovine serum albumin (BSA), and methanol were obtained from Sigma-Aldrich (St. Louis, MO). FACS/Lyse solution was obtained from BD Biosciences.
+ Open protocol
+ Expand
2

Multiparametric Flow Cytometry of Immune Cell Subsets

Check if the same lab product or an alternative is used in the 5 most similar protocols
Healthy donor and patient PBMCs were obtained by using Ficoll density centrifugation and stained for 30 minutes at 48C with the following mouse anti-human antibodies: CXCR5-allophycocyanin (APC; 51505) from R&D Systems (Minneapolis, Minn); CCR7-phycoerythrin (PE)-CF594 (150503), CD27 V450 (M-T271), CD27 Brilliant Violet (M-T271), CD38-PE-Cy7 (HIT2), CD21-PE (B-ly4), CD3-APC-H7 (SK7), CD5-Alexa Fluor 700 (UCHT), CD4-APC (RPA-T4), CD4-Brilliant Violet 605 (RPA-T4), CD45RA-Alexa Fluor 700 (HI100), CD8-V500 (RPA-T8), CD8-fluorescein isothiocyanate (FITC; HIT8a), IgM-APC (G20-1273), IgD-FITC (IA6-2), and CD95-PE-Cy7 (DX2) from BD PharMingen (San Jose, Calif); CD19-peridinin-chlorophyll-protein complex-Cy5.5 (HIB19), CD10-APC (CB-CALLA), and CD31-APC (WM59) from eBioscience (San Diego, Calif); CD14-PE-Cy7 (RMO52), CD56-PE (N901), CD4-PE (13B8.2), T-cell receptor (TCR)-Vb11-FITC (C21), and TCR-Va24-PC-7 (C15) from Beckman Coulter; and CD8-V450 (RPA-T8) from BD Horizon (BD Biosciences, Franklin Lakes, NJ). Stained cells were analyzed on a BD LSR Fortessa cytometer. Data were processed with FlowJo X software (TreeStar, Ashland, Ore) and sketched with Prism 6.0 software (GraphPad Software, La Jolla, Calif).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!