The largest database of trusted experimental protocols

Succinic anhydride

Manufactured by J&K Scientific
Sourced in China

Succinic anhydride is a chemical compound with the molecular formula (CH2CO)2O. It is a cyclic anhydride that serves as a versatile intermediate in organic synthesis, particularly in the production of various chemicals and pharmaceuticals.

Automatically generated - may contain errors

7 protocols using succinic anhydride

1

Synthesis and Characterization of Multifunctional Polymer Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
(3-Mercaptopropyl) trimethoxysilane (97%, J&K), 2,2'-dithiodipyridine (98%, Energy Chemical), poly(ethylene glycol) methyl ether (PEG-OH, Mn = 750 g/mol, 98%, Energy Chemical), thionyl chloride (97%, J&K), 2-mercaptoethylamine hydrochloride (MCA, 99%, Energy Chemical), 1-(2-aminoethyl)piperazine (AEPZ, 97%, Aldrich), diisopropanolamine (DIAD, 98%, Energy Chemical), phthalimide (97%, Energy Chemical), triphenylphosphine (99%, Energy Chemical), hydrazine hydrate (95%, J&K), triethylamine (TEA, 99%, Beijing Chemical Works), succinic anhydride (99%, J&K), N, N'-bis(acryloyl)cystamine (BAC, 98%, Fluka), β-CD ( > 95%, TCI) was dried at 70 °C under vacuum for 24 h before use. Cell counting kit-8 was purchased from Beyotime Biotechnology. DMEM (Corning) with 4.5 g /L glucose, l-glutamine, without sodium pyruvate was purchased from Beijing BioDee Biotechnology Co. Ltd. MCF-7 cell lines were purchased from the American type Culture Collection (ATCC, Rockville, MD). Other reagents were commercially obtained from Beijing Chem. Co. and used without further purification.
+ Open protocol
+ Expand
2

Zeb1/2 Gene Silencing Nano-Delivery

Check if the same lab product or an alternative is used in the 5 most similar protocols
Branched polyethyleneimine (PEI, Mw 2 kDa), 2-(N,N-diethylamino)ethyl methacrylate (DEA), Cysteamine (95%), Azobisisobutyronitrile (AIBN), Succinic anhydride (SA), cis-Aconitic anhydride, dimethyl sulfoxide (DMSO), Triethylamine (TEA), pyridine, and acetone were purchased from J&K Scientific Ltd. (Beijing, China). ZrOCl2∙8H2O, Tetrakis (4-carboxyphenyl)porphyrin (TCPP), N,N-Dimethylformamide (DMF), N-ethyl-N-(3-(dimethylamino)-propyl) carbodiimide hydrochloride (EDC), and N-hydroxysuccinimide (NHS) were supplied by Aladdin Industrial Co., Ltd. (Shanghai, China). The siZEB1 (GTT​GTT​CTG​CCA​ACA​GTT​G) and siZEB2 (GGC​CGA​ATG​AGA​AAC​AAT​A) target both human and mice’s genes, and Cy5-labeled siZEB1/2 were designed and synthesized by RiboBio (Guangzhou, China). Lipofectamine 2000 was purchased from Invitrogen (Carlsbad, United States), and the LPS was obtained from Sigma-Aldrich (Missouri, United States). The Cell Counting Kit-8 (CCK-8) was bought from Boster Biological Technology (Wuhan, China). DAPI and total RNA Reagent Trizol were purchased from Life Technologies (New York, United States). The PrimeScript®RT Reagent Kit with gDNA Eraser was provided by TaKaRa (Beijing, China). Quantitative real-time qPCR kits (iTaq™ universal SYBR® Green Supermix) were purchased from Bio-Rad (California, United States).
+ Open protocol
+ Expand
3

Anhydride Synthesis and Cytokine Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dex and succinic anhydride were purchased from J&K Scientific Ltd (Beijing, China). Glutaric anhydride was purchased from Beijing Bailingwei Technology Co., Ltd. (Beijing, China). Adpic anhydride was purchased from Nanjing Kangmanlin Biology Technology Co., Ltd. (Nanjing, China). Phthalic anhydride was purchased from Adamas-beta Co., Ltd. (Shanghai, China). Mouse TNF-α DuoSet ELISA (DY410-05) and mouse IL-6 DuoSet ELISA (DY406-05) were obtained from R&D SYSTEMS® (Minneapolis, MN, USA). All other used agents were of analytical grade.
+ Open protocol
+ Expand
4

Dextran Uptake and KRASG12V Expression in BxPC-3 Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents were purchased from commercial sources: FITC-labeled 4 kDa, 70 kDa, 150 kDa dextrans (Sigma, USA), TMR 70 kDa-labeled dextran (Life Technologies), TP (Chengdu Purifa, China), succinic anhydride (J&K Scientific, China), DMAP (Macklin, China), CDI (Macklin, China), esterase from porcine liver (Sigma, USA), EIPA (MedChemExpress, USA), and LysoTracker (Life Technologies).
Plasmids were obtained from Addgene (USA): pBABE-Puro-KRASG12V was a gift from Christopher Counter and the pBABE-Puro vehicle control was a gift from Hartmut Land, Jay Morgenstern and Bob Weinberg. All plasmids were packaged into lentiviruses with RSV, VSV, and pMDL and transduced into BxPC-3 cells via infection and selected under puromycin pressure (~1.5 µg/ml).
Antibodies used for immunohistochemical staining were from Servicebio (China): anti-Ki67 (GB111141), anti-EpCAM (GB11274), anti-CD3 (GB13014), anti-CD4 (GB13064-2), anti-CD8 (GB13429), anti-CD45 (GB11066), anti-IFN-γ (GB11107-1) and anti-TNF-α (GB11188).
+ Open protocol
+ Expand
5

Paclitaxel-Loaded Polymeric Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Paclitaxel was purchased from Nanjing Jingzhu Bio-technology Co., Ltd. (Nanjing, China). Pyrene (purity 97%) was purchased from Shanghai Jingchun Bio-technology Co., Ltd. (Shanghai, China). Dialysis tube (MWCO 2000/350) was obtained from Shanghai Lvniao Technologies, Inc. (Shanghai, China). Glutathione (GSH), 4-(dimethylamino-pyridin (DMAP, purity > 98%), 3, 3′-Dithiodipropionic acid (DTDP, purity > 98%), Acetyl chloride (purity > 98%), CaH2 (purity > 98.5%) and N, N'-Dicyclohexyl-carbodiimide (DCC, purity > 98%) were purchased from Aladdin Reagent Co., Ltd. (Beijing, China). Succinic anhydride (purity > 99% GC), Acetonitrile hyper grade for HPLC, DMSO-d6, and CDCl3 were purchased from J & K Scientific Ltd. (Beijing, China). 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyl Tetrazolium bromide (MTT, 5 mg/mL Sigma-Aldrich), Dulbecco's modified Eagle medium (DMEM), penicillin-streptomycin (Amresco, USA), 0.25% (w/v) trypsin-EDTA solution and fetal bovine serum (FBS, Gibco, USA) were purchased from Sigma-Aldrich. All chemicals were analytical grade and used without further treatment. The mPEG-PBLA was synthesized according to the literature (41 (link)) and dithiodipropionic anhydride was also synthesized according to previous report (42 (link)).
+ Open protocol
+ Expand
6

Chitosan-Dopamine Hydrogel Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chitosan (Mn = 100 000–300 000 Da), dopamine hydrochloride (DA) (purity 98%) and succinic anhydride were obtained from J&K. Polyethylene glycol monomethyl ether (mPEG), methacrylate anhydride (94%), glycidyl methacrylate (≥97%) and zinc chloride were purchased from Sigma-Aldrich. All other reagents were used without further purification.
+ Open protocol
+ Expand
7

Synthesis of Fluorescent Polymer Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
N,N-Dimethylformamide, 9-anthracenemethanol, toluene, poly(ether diamine) (Jeffamine D230), and 4-methylbenzenesulfonic acid were purchased from Adams-Beta Co. Ltd. (Shanghai, China). 2-Mercaptoethanol and succinic anhydride were purchased from J&K Scientific Ltd. Chloroform, polybutadiene (PB) (Mw ∼ 200000), and 1,4,5,8-naphthalenetetracarboxylic dianhydride were purchased from Sigma-Aldrich. All the reagents were used as received.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!