The largest database of trusted experimental protocols

Signa hde 1.5 t

Manufactured by GE Healthcare

The Signa HDe 1.5 T is a magnetic resonance imaging (MRI) system designed and manufactured by GE Healthcare. It operates at a magnetic field strength of 1.5 Tesla, which is a common field strength used in clinical MRI applications.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using signa hde 1.5 t

1

Multimodal MRI Assessment of Lymph Node Characteristics

Check if the same lab product or an alternative is used in the 5 most similar protocols
The Signa HDe 1.5 T superconducting MRI imager provided by GE was used to scan the neck cross section, coronal plane, and sagittal plane using conventional spin echo (SE). T1WI and T2WI modes and using NMR diffusion weighting imaging (DWI) to measure the apparent diffusion coefficient (ADC). More than 2 radiologists read the image, and the short axis diameter of the lymph node tissue, signal intensity (uniform/uneven), margin (regular/irregular), boundaries (clear/unclear), T1WI signal intensity (high intensity/equal intensity, low intensity), T2WI signal intensity (high intensity/equal intensity, low intensity), ADC value were recorded.
+ Open protocol
+ Expand
2

Lumbar Spine MRI Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Magnetic resonance imaging scanners named Signa Hde 1.5 T and Discovery MR750 (3 T) from General Electric Company (GE) were used. After lunching the exam to be ready for the diagnosis, the spinal phasing front coil is used, and the patient wearing hearing protection is instructed not to move during the examination. The lumbar scan protocol was used during scanning. The scanning sequence and azimuth included the FSE-T1WI sequence in the sagittal plane, the FSE-T2WI sequence in the sagittal plane, the FSE-T2WI sequence in the sagittal plane, and the FSE-T2WI sequence in the transverse plane. Due to the possibility of disc-bone overlap in cross-sectional T2WI sequences, which affects image representativeness, only sagittal T2WI sequences were used in this study. The main parameters included TR 2000 ms, TE 120 ms, layer thickness 4 mm, layer spacing 0.5 mm, matrix 320*224, average acquisition times twice, and field of view 320 mm*320 mm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!