The largest database of trusted experimental protocols

5 protocols using zinc 2 nitrate

1

Synthesis of ZnO Nanoparticles from Plant

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals used in this experiment were of analytical grade and purchased from local suppliers. Analytical grade compounds of zinc (II) nitrate [Zn (NO3)2.6H2O], and sodium hydroxide were obtained from Merck. Commercial ZnO-NPs (US3580, NanoSany, Iran) (35–45 nm, 99% purity, spherical shape) were purchased from NanoSany, Iran. The fresh plant materials were obtained from local traders (Ardabil, Iran) and further identified by a botanist.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Losartan-Zinc(II) Complex

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals were of analytical grade and used without further purification. Losartan, potassium salt was purchased from Parafarm and Zinc(II) nitrate (Merck) was used as supplied. A sodium silicate solution (14% NaOH-27% SiO 2 , SiO 2 .NaOH, Sigma-Aldrich) was used for the diffusion method. Infrared spectra of powdered samples were measured with a Bruker IFS 66 FTIR-spectrophotometer from 4000 to 400 cm -1 using the KBr pellet technique. FT-Raman spectra were measured using the FRA 106 Raman accessory with germanium detector operating at liquid nitrogen temperature. A continuouswave Nd/YAG laser working at 1064 nm was employed for Raman excitation. Elemental analyses for carbon, hydrogen and nitrogen were performed using a Carlo Erba EA 1108 analyzer. Thermogravimetric analysis (TGA) were measured with a Shimadzu system (model TG-50), working in an oxygen flow of 50 mL/min and at a heating rate of 10 °C/min. Sample quantities ranged between 5 and 10 mg. Electronic absorption spectra were recorded on a Hewlett-Packard 8453 diode-array spectrophotometer, using 1-cm quartz cells. Fluorescence spectra were measured using a Shimadzu RF-6000 spectrophotometer. The molar conductance of the complex was measured on a Conductivity TDS Probe -850,084, Sper Scientific Direct, using 10
+ Open protocol
+ Expand
3

Reagent Preparation for Analytical Studies

Check if the same lab product or an alternative is used in the 5 most similar protocols
Deionized water was used for the preparation and dilution of all solutions. The chemicals applied in this work were all of analytical grade. A Pb(II) stock solution of 1000 mg L−1 was prepared from the nitrate salt and diluted daily for designed experiments. α-Benzoin oxime, iron(III) chloride, phenol, sodium fluoride, sodium phosphate, nickel(II) nitrate, hexahydrate, sodium nitrate, lead(II) nitrate, cobalt(II) nitrate, zinc(II) nitrate, sodium carbonate, potassium chloride, magnesium nitrate hexahydrate, calcium chloride, sodium sulfate, and iron(II) nitrate were purchased from Sigma (St. Louis, MO, USA). Sodium hydroxide, hydrochloric acid, nitric acid, and hydrogen peroxide were purchased from Merck (Darmstadt, Germany).
+ Open protocol
+ Expand
4

Multifunctional Aptamer-Based Sensing Platform

Check if the same lab product or an alternative is used in the 5 most similar protocols
Gold(iii) chloride hydrate, human serum type AB (male), silver nitrate, NaBH4, thallium(i) chloride, cesium(i) chloride, rubidium(i) chloride, sodium chloride, magnesium(ii) chloride, iron(iii) nitrate, potassium(i) chloride, lead(ii) nitrate, silver(i) nitrate, lithium(i) chloride, nickel(ii) nitrate, streptavidin, PDDA (15%), zinc(ii) nitrate and mercury(ii) nitrate cadmium chloride(ii) were purchased from Sigma-Aldrich, Canada. Phosphoramidites dmf-dG-CE, dT-CE, dA-CE, Ac-dC-CE and biotin modifier were purchased from Glen Research, USA. ACN, TEAA, and anhydrous acetonitrile were purchased from BDH, VWR, Canada. Sample and absorption pad (CFSP223000) obtained from Millipore Co, Bedford, MA. Pullulan bought from Polysciences, Warrigton, PA. NC membrane was purchased from Sartorius Stedim Biotech, Germany and conjugate pad was purchased from Ahlstrom Munksjo, Finland. The aptamers used in this study were reported in the literature7,37,38 and the aptamers were included in the ESI Table S1.
+ Open protocol
+ Expand
5

Preparation of Metal Standard Solutions

Check if the same lab product or an alternative is used in the 5 most similar protocols
Hexaammineruthenium(III) chloride, lead, cadmium and bismuth standards for ICP, iron(III) nitrate, copper(II) nitrate, cobalt(II) nitrate, nickel(II) nitrate and zinc(II) nitrate were acquired from Sigma-Aldrich. Bismuth(III) nitrate as well as acetic acid, sodium acetate and citric acid and were purchased from Merck. Carbon sensor paste (C10903P14) was purchased from Gwent Electronics. Adhesive copper tape was acquired from EMS (Electron Microscopy Sciences). All chemicals were of analytical grade. Solutions were prepared by using ultrapure water employing a Milli-Q Millipore water purification system. Heavy metal solutions were prepared daily by an appropriate dilution of standards in 0.1 M acetate buffer.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!