Lct premier mass spectrometer

Manufactured by Waters Corporation
Sourced in United States

The LCT Premier mass spectrometer is a high-performance liquid chromatography (LC) instrument designed for accurate mass measurement and molecular characterization. It utilizes time-of-flight (TOF) technology to provide precise mass detection and identification of compounds.

Automatically generated - may contain errors

27 protocols using lct premier mass spectrometer

1

Characterization of Synthesized Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available chemicals were purchased from Fujifilm Wako Pure Chemical Co. (Osaka, Japan), unless otherwise stated. Absorbance was measured using a Synergy™ MX microplate reader (BioTek Instruments, Inc., Winooski, VT, USA). A Bruker AMX 500 instrument (Bruker BioSpin K.K., Bruker Instruments, Billerica, MA, USA) was used to obtain nuclear magnetic resonance (NMR) spectra and residual solvents were used as internal standards (pyridine-d5: 1 H 7.22 ppm, 13 C 135.91 ppm).
Mass spectra were obtained using an LCT-Premier mass spectrometer (Waters Corp., Milford, MA, USA) or a Jeol JMS-T100GCV (Jeol Ltd., Tokyo, Japan). For ultra-high-performance liquid chromatography (UPLC)-mass spectrometry (MS) analysis, a Waters Acquity UPLC system (Waters Corp., Milford, MA, USA) was linked to an LCT-Premier mass spectrometer.
+ Open protocol
+ Expand
2

Isolation and Characterization of Bioactive Compounds from Eurycoma longifolia

Check if the same lab product or an alternative is used in the 5 most similar protocols
Unless otherwise stated, commercially available chemicals were purchased from Wako Pure Chemical Industries, Ltd. (Osaka, Japan). E. longifolia root (Batch No. SL.1A.2015.PB) was supplied by Merapi Farma Herbal Co. (Yogyakarta, Indonesia).
Absorbance was measured using a Synergy™ MX microplate reader (BioTek Instruments, Inc., Winooski, VT, USA). A Bruker AMX 500 instrument (Bruker BioSpin K.K., Bruker Instruments, Billerica, MA, USA) was used to obtain NMR spectra and residual solvents were used as an internal standard (pyridine-d 5 : 1 H 7.22 ppm, 13 C 135.91 ppm). Mass spectra were obtained using a LCT-Premier mass spectrometer (Waters Corp., Milford, MA, USA). For the LC-MS analysis, Waters Acquity UPLC system (Waters Corp., Milford, MA, USA) was combined with LCT-Premier mass spectrometer (Waters Corp., Milford, MA, USA). The EZR was used for the statistical tests. 22
+ Open protocol
+ Expand
3

Synthesis and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents and dry solvents were purchased from various chemical suppliers (Aldrich, Acros Organics, ChemImpex, TCI America, and Bachem) and were used as obtained. Silica gel (230–450 mesh) used for flash chromatography was purchased from Sorbent Technologies (Atlanta, GA). Thin layer chromatography was performed using Analtech silica gel plates. Visualization was accomplished using UV light and/or iodine. The 1H NMR were recorded in CDCl3 or DMSO-d6 using a Varian XL-400 spectrometer and are reported relative to TMS (δH = 0.00 ppm). Chemical shifts are reported in ppm and spin multiplicities are represented by the following signals: s (singlet), d (doublet), dd (doublet of doublets), t (triplet), q (quartet) and m (multiplet). Melting points were recorded on a Mel-Temp apparatus and are uncorrected. High resolution mass spectrometry (HRMS) was performed at the University of Kansas Mass Spectrometry lab using an LCT Premier mass spectrometer (Waters, Milford, MA) equipped with a time of flight mass analyzer and an electrospray ion source. The purity of the compounds was established using HPLC and was >95%.
+ Open protocol
+ Expand
4

Mass Spectrometry of Organic Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
We collected the mass spectra using both laser desorption ionization (LDI) and electrospray ionization (ESI) mass spectroscopy. ESI mass spectroscopy was performed on a Waters LCT Premier mass spectrometer. MassLynx was used as the software to collect spectra. Each ESI mass spectrum shown in this work was an average of 55 mass spectra collected in 1 minute with 0.1 second between every two one-second scans. Samples were diluted about 10 times before injection. For LDI measurements, we used the linear mode of the Comstock RTOF-210 mass spectrometer with a pulsed Nd:YAG laser at 355 nm (New Wave Research Polaris II). The laser power was less than 400 μJ/pulse. All the LDI mass spectra exhibited here were averaged from 200~500 scans. Sample solutions were applied to a solid copper tip, dried in air to form a thin film, and then inserted into the ion source.
+ Open protocol
+ Expand
5

Synthesis and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents and dry solvents were purchased from various chemical suppliers (Aldrich, Acros Organics, Chem-Impex, TCI America, and Bachem) and were used as obtained. Silica gel (230–450 mesh) used for flash chromatography was purchased from Sorbent Technologies (Atlanta, GA). Thin layer chromatography was performed using Analtech silica gel plates. Visualization was accomplished using UV light and/or iodine. NMR spectra were recorded in CDCl3 or DMSO-d6 using a Varian XL-400 spectrometer. Melting points were recorded on a Mel-Temp apparatus and are uncorrected. High resolution mass spectrometry (HRMS) was performed at the University of Kansas Mass Spectrometry lab using an LCT Premier mass spectrometer (Waters, Milford, MA) equipped with a time of flight mass analyzer and an electrospray ion source. The purity of the compounds was established using HPLC and was >95%.
+ Open protocol
+ Expand
6

Characterizing pABOL Reduction Byproducts

Check if the same lab product or an alternative is used in the 5 most similar protocols
The byproduct of pABOL reduction
was characterized using a Waters LCT Premier mass spectrometer. Samples
were ionized using electrospray ionization (ESI).
+ Open protocol
+ Expand
7

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H and 13C NMR spectra were recorded at 25 °C on the Brucker Avance III 400 MHz. Unless otherwise specified, chemical shifts δ were expressed in parts per million (ppm) based on the residual solvent signal in DMSO-d6 (δ 2.50 ppm) or tetramethylsilane (TMS) in CDCl3 (δ 0.00 ppm), and coupling constants J are given in Hz. Coupling patterns are abbreviated as s (singlet), d (doublet), t (triplet), q (quartet), quin (quintet), ABq (AB quartet), and m (multiplet). Electrospray mass spectra were recorded on a Waters LCT Premier mass spectrometer in positive ion mode. Reverse phase HPLC was performed using Waters HPLC system equipped with Waters-1525 solvent delivery systems and Waters 2998 UV detector. Separation was achieved on a semi-preparative Phenomenex (Torrance, CA) Jupiter® 5μm C18 300Å column (5 micron, 250 × 10.00 mm, Part Number: 00G-4053-N0) at a flow rate maintained at 4.0 mL/min. A solvent system composed of water containing 0.1% TFA as solvent A and acetonitrile containing 0.1% TFA as solvent B was used over the stated gradient. The column effluent was monitored with a UV/Vis detector set at 760 nm.
+ Open protocol
+ Expand
8

Native Mass Spectrometry of G-Quadruplexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
All mass spectra were obtained in negative ion mode with injection concentrations of 5 μM in G-quadruplexes and 5 μM internal standard dT6. Native electrospray mass spectra of oligonucleotides were obtained using several instruments, with similar results. (1) On an LCT Premier mass spectrometer (Waters, Manchester, UK), the ESI source voltage was set to 2.2 kV with a desolvation temperature of 60°C. Unless otherwise mentioned, the ion guide 1 voltage is 50 V. The source pressure was increased to 35 mbar. This pressure is measured using a Center Two probe (Oerlikon Leybold Vacuum, Cologne, Germany). The syringe injection flow was fixed to 200 μL/h. In all experiment 5 μM dT6 (monoisotopic mass 1762.318 Da) was used as internal standard. (2) An Exactive ESI-Orbitrap mass spectrometer (Thermo Scientific, Bremen, Germany) was also used to monitor the titration of TG4T by KCl. In this case, ESI spray voltage and capillary voltage are 2.75 kV and –20 V, respectively. Capillary temperature is set to 150°C. Tube lens and skimmer voltage are fixed to –180 V and –10 V. In order to help the desolvation process to occur, the HCD cell voltage is set to 10 eV and the cell pressure is 2.5 × 10–5 mbar.
+ Open protocol
+ Expand
9

Metal Complex Formation of Peptoid Oligomers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples for MS analysis were prepared shortly before measurements. In a typical experiment, a solution of peptoid oligomers (100–200 μL of 0.05 mM) in MeOH or ACN was treated with metal solution (5 mM in H2O or ACN) and the mixture was stirred for 30 minutes prior to MS analysis. Mass spectrometry analysis of the metal complexes was performed on a Waters LCT Premier mass spectrometer under electrospray ionization (ESI), direct probe ACN : H2O (70 : 30), flow rate 0.3 mL min–1.
+ Open protocol
+ Expand
10

Synthesis and Characterization of tert-Butyl Chloride

Check if the same lab product or an alternative is used in the 5 most similar protocols

Tert‐butyl chloride was synthesised at the Deuteration Facility at ISIS Neutron and Muon Source, STFC Rutherford Appleton Laboratory in Oxfordshire, UK. Phosphorus trichloride (99%), magnesium ribbon (>99.5%), copper(I) iodide (>99.5%) and lithium bromide (>99%) were purchased from Sigma Aldrich and used as received. The glovebox used in this work was MBraun Labmaster dp, operating typically under argon, at or below 0.6 ppm of H2O and O2. 13C and 31P NMR spectra were recorded on a Bruker Avance DPX 400 MHz spectrometer. Electrospray mass spectrometry measurements were performed using a Waters LCT Premier mass spectrometer.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.