Mp150 hardware

Manufactured by Biopac
Sourced in United States

The MP150 is a versatile data acquisition hardware system designed for scientific research and physiological measurements. It provides high-quality signal acquisition and processing capabilities for a wide range of applications.

Automatically generated - may contain errors

4 protocols using mp150 hardware

1

Sympathetic Activity Assessment Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sympathetic activity was calculated from heart rate (HR) and HRV that was acquired using Zephyr physiology monitoring system with MP150 hardware (BIOPAC Systems, CA, USA) and AcqKnowledge 3.9 software. Short-term HRV was acquired in compliance to the guidance of Task Force on HRV using previously standardized protocol.30 Briefly, the volunteers were habituated to test environment in a relaxed sitting position for 30 minutes to minimize inter-variability among the subjects due to tobacco intake prior to data acquisition. Data was acquired for beat-to-beat intervals, HR and breathing rate in block durations of 1 minute at a sampling rate of 25 Hz in sitting position while maintaining a breathing rate of 15–20 breaths per minute for 3 minutes. Subsequently, HR and HRV was acquired for 5 minutes under normal breathing for analysis purposes. A consistent 5-minute RR interval series was selected after removal of artefacts and ectopic from the recorded tachogram, for analysis of HRV parameters. Nonparametric Fast Fourier Transform method was used to determine powers of low-frequency (LF) domain, high-frequency (HF) domain and the LF:HF ratio. While frequency in the range of 0.04–0.15 Hz was considered as LF, frequency between 0.15 and 0.4 Hz was considered as HF.
+ Open protocol
+ Expand
2

Physiological Signal Acquisition and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
All physiological signals were acquired using Biopac Systems, Inc. MP150 hardware (Biopac Systems Inc., Goleta, CA, USA). The MP150 digitally sampled signals at 1000 Hz. Physiological data were acquired using Biopac AcqKnowledge 4.4 software in order to detect and remove movement artifact. ConMed Suretrace conductive Ag/AgCl adhesive pre-gelled electrodes were used for collection of ICG and ECG data. All physiological measures were collected in real time, then separately averaged within pre-task, task, and post-task epochs prior to statistical analyses.
+ Open protocol
+ Expand
3

Noninvasive Assessment of Vagal Tone

Check if the same lab product or an alternative is used in the 5 most similar protocols
Vagal tone was assessed using noninvasive Electrocardiogram (ECG) recordings, obtained with a Biopac ECG amplifier (Goleta, CA) according to accepted guidelines (Fox & Leavitt, 1995 ). Participants were instructed to sit quietly without moving for 5 minutes. We used a modified Lead II configuration, placing electrodes on the right clavicle, left lower torso, and right leg (ground). ECG data, sampled at 1.0 kHz, were collected using Biopac MP150 hardware and Acknowledge software. Trained raters, blinded to violence exposure of participants, visually inspected automatic R-peak detection of the ECG data using Mindware Heart Rate Variability (HRV) Software (Mindware Technologies, Gahannah, OH). Visual inspection focused on detecting ectopic beats and confirming accurate detection of R-peaks in the ECG waveform. From IBI time series, we calculated RSA in 1-minute bins. To calculate RSA, the HRV module detrended the data using a first order polynomial to remove the mean and any linear trends, cosine tapered the data, submitted it to Fast Fourier Transformation, and took the natural log integral of high frequency power in the appropriate respiratory frequency band based on participant age (0.24–0.40 Hz for 8–12 years of age, and 0.18–0.40 Hz for 13–16 years of age), (Shader et al., 2018 (link)).
+ Open protocol
+ Expand
4

Noninvasive Cardiac Variability Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Continuous cardiac measures were recorded noninvasively according to accepted guidelines (Sherwood et al., 1990 (link)). Electrocardiogram (ECG) recordings were obtained with a Biopac ECG amplifier (Goleta, CA) using a modified Lead II configuration (right clavicle, left lower torso, and right leg ground). Biopac MP150 hardware and Acknowledge software were used to acquire the ECG data (sampled at 1.0 kHz). ECG data were scored by trained professionals blind to group status. Signals were visually inspected and scored using Mindware Heart Rate Variability (HRV) Software (Mindware Technologies, Gahannah, OH).
RSA was calculated from interbeat interval time series using spectral analysis conducted in Mindware HRV Software. RSA was calculated for the frequency band 0.12–0.40Hz.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!