The largest database of trusted experimental protocols

13 protocols using autospec premier p776 mass spectrometer

1

Spectroscopic Characterization and Quantum Calculations

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations and ECD curves were determined on a Chirascan CD spectrometer (Applied Photophysics Ltd., Surrey, UK). IR spectra were obtained on a Nicolet iS10 FT-IR spectrometer (Thermo Fisher Scientific, Waltham, MA, USA). NMR spectra were recorded on a Bruker Avance III 500 NMR spectrometer (Bruker Corp., Billerica, MA, USA). Low- and high-resolution EI and ESI+ mass spectra were measured on an Autospec Premier P776 mass spectrometer (Waters Corp., Milford, MA, USA) and an Agilent G6230 TOF mass spectrometer (Agilent Technologies Inc., Santa Clara, CA, USA), respectively. Column chromatography (CC) was carried out with silica gel (200–300 mesh, Qingdao Haiyang Chemical Co., Qingdao, China), RP-18 (AAG12S50, YMC Co., Ltd., Kyoto, Japan), and Sephadex LH-20 (GE Healthcare, Uppsala, Sweden). Thin-layer chromatography (TLC) was performed with precoated silica gel plates (GF-254, Qingdao Haiyang Chemical Co., Qingdao, China). Quantum chemical calculations were run with Gaussian 09 software (Gaussian, Inc., Wallingford, CT, USA).
+ Open protocol
+ Expand
2

Comprehensive Analytical Techniques for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
UV spectra were recorded with a Shimadzu UV-2401A spectrophotometer. IR spectra were recorded on Bruker Tensor 27 spectrometer with KBr pellets. 1D and 2D NMR spectra were carried out on Bruker AM-400, DRX-500, or AVANCE III-600 spectrometers. Chemical shifts were reported using TMS as the internal standard. ESI–MS were run on Shimadzu UPLC–IT–TOF–MS instrument. HR–ESI–MS spectra were measured using Agilent G 6230 TOF MS (Agilent). EI–MS and HR–EI–MS spectra were measured with a Waters AutoSpec Premier P776 mass spectrometer (Waters, Milford, MA, USA).Crystal analysis were performed on a Bruker APEX DUO diffractometer equipped with an APEX II CCD, using Cu Kα radiation (λ = 1.54178 Å). Cell refinement and data reduction were performed with Bruker SAINT. Column chromatography (CC) was performed on silica gel (100–200 or 200–300 mesh; Qingdao Marine Chemical Co. Ltd., Qingdao, China), Sephadex LH-20 (GE Healthcare Bio-Sciences AB, Sala, Sweden) and MPLC was performed on a Lisui EZ Purify III System packed with MCI gel (CHP20P, 75–150 mm; Mitsubishi Chemical Corporation, Tokyo, Japan). Precoated silica gel GF254 plates (Qingdao Haiyang Chemical Co. Ltd.) were used for thin-layer chromatography (TLC). Fractions were monitored by TLC and spots were visualized by Dragendorff’s reagent.
+ Open protocol
+ Expand
3

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were measured on a Bruker Avance III 500 NMR spectrometer (Bruker Corp., Billerica, MA, USA). Low and high resolution EI mass spectra were determined on an Autospec Premier P776 mass spectrometer at 70 eV (Waters Corp., Milford, MA, USA). ECD spectra were acquired on a Chirascan CD spectrometer (Applied Photophysics Ltd., Surrey, UK). IR spectra were recorded on a JASCO FT/IR-4100 spectrometer (JASCO, Tokyo, Japan). Optical rotations were obtained on an SGW-3 polarimeter with a 2 mL (length 10 cm) cell (Shanghai Shenguang Instrument Co., Ltd., Shanghai, China). HPLC separation was operated on an Agilent HPLC system (1260 infinity quaternary pump, 1260 infinity diode-array detector) using an Eclipse SB-C18 (5 μm, 9.4 × 250 mm) column (Agilent Technologies Inc., Santa Clara, CA, USA). Column chromatography (CC) was carried out with silica gel (200–300 mesh, Qingdao Haiyang Chemical Co., Qingdao, China), RP-18 (AAG12S50, YMC Co., Ltd., Kyoto, Japan), and Sephadex LH-20 (GE Healthcare, Uppsala, Sweden). Thin-layer chromatography (TLC) was performed with precoated silica gel plates (GF-254, Qingdao Haiyang Chemical Co., Qingdao, China).
+ Open protocol
+ Expand
4

Phytochemical Analysis of Natural Product

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were obtained with a Jasco P-1020 polarimeter. UV spectra were measured on Shimadzu UV-2401A spectraphotometer. IR spectra were detected on a Bruker Tensor-27 infrared spectrophotometer with KBr pellets. 1D and 2D NMR spectra were recorded on Bruker AV-400, and Avance III-600 MHz spectrometers with TMS as the internal standard. Chemical shifts (δ) were expressed in ppm with reference to the solvent signals. HRESIMS analysis and HREIMS were determined on API QSTAR time-of-flight spectrometer and on Waters Auto spec Premier P776 mass spectrometer. Semi-preparative HPLC was performed on an Agilent 1100 liquid chromatography with a Zorbax SB-C18 (9.4 mm × 25 cm) column. Column chromatography was performed on Sephadex LH-20 (GE Healthcare), Silica gel (100–200 and 200–300 mesh, Qingdao Marine Chemical Co., Ltd., Qingdao, China), and Amphichroic RP-18 gel (40–63 μm, Merck, Darmstadt, Germany) and MCI gel (75–150 μm, Mitsubishi Chemical Corporation, Tokyo, Japan). Fractions were monitored by TLC and spots were visualized by heating silica gel plates sprayed with 10 % H2SO4 in EtOH.
+ Open protocol
+ Expand
5

Synthesis and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All compounds were fully characterized
by spectroscopic data analysis. The NMR spectra were recorded on a
Bruker DRX500 or DRX600 NMR spectrophotometer (Bruker Biospin GmbH,
Ettlingen, Germany); chemical shifts (δ) are expressed in ppm, J values are given in Hz, and deuterated dimethyl sulfoxide
(DMSO)-d6 or CDCl3 was used
as solvent. The IR spectra were recorded on a Fourier transform infrared
(FT-IR) Avatar 360 spectrophotometer (Thermo Nicolet Corp., Madison
WI) using the KBr pellet technique. The reactions were monitored by
thin-layer chromatography (TLC) using silica gel GF254 (EMD
Millipore, Billerica, MA). The melting points were determined on an
XT-4A melting point apparatus and are uncorrected. High-resolution
mass spectra time-of-flight (HRMS-TOF) were performed on an AutoSpec
Premier P776 mass spectrometer (Waters Corp., Milford,. MA). X-ray
diffraction analysis was performed using an Apex Duo diffractometer
(Bruker AXS GmbH., Karlsruhe, Germany). All chemicals and solvents
were used as received without further purification unless otherwise
stated. Column chromatography was performed on silica gel (200–300
mesh).
The materials were purchased from Adamas-β Ltd.
(Shanghai China). Compounds 1 were prepared according
to the literature.17 (link) Compounds 2 were prepared according to the literature.38 (link)
+ Open protocol
+ Expand
6

Comprehensive Analytical Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were obtained on a JASCO P-1020 digital polarimeter (Horiba, Kyoto, Japan). UV spectra were recorded on a Shimadzu UV-2401PC UV–visible recording spectrophotometer (Shimadzu, Kyoto, Japan). 1D and 2D NMR spectra were obtained on a Bruker Avance III 600 MHz spectrometer (Bruker Corporation, Karlsruhe, Germany). HRESIMS were recorded on an Agilent 6200 Q-TOF MS system (Agilent Technologies, Santa Clara, CA, USA). HREIMS were obtained on a Waters Autospec Premier P776 mass spectrometer. Single crystal X-ray diffraction was performed on an APEX II DUO spectrophotometer (Bruker AXS GmbH, Karlsruhe, Germany). Sephadex LH-20 (Amersham Biosciences, Uppsala, Sweden) and silica gel (Qingdao Haiyang Chemical Co., Ltd) were used for column chromatography (CC). Medium pressure liquid chromatography (MPLC) was performed on a Büchi Sepacore System equipped with pump manager C-615, pump modules C-605 and fraction collector C−660 (Büchi Labortechnik AG, Flawil, Switzerland), and columns packed with Chromatorex C-18 (40–75 μm, Fuji Silysia Chemical Ltd., Kasugai, Japan). Preparative high performance liquid chromatography (prep-HPLC) were performed on an Agilent 1260 liquid chromatography system equipped with Zorbax SB−C18 column (particle size 5 μm, dimension 9.4 mm × 150 mm, flow rate 8 mL/min, respectively) and a DAD detector (Agilent Technologies, Santa Clara, CA, USA).
+ Open protocol
+ Expand
7

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Jasco model 1020 digital polarimeter (Jasco Corp., Tokyo, Japan) was used to measure optical rotations. UV and IR data were obtained using a Shimadzu UV2401PC spectrophotometer (Shimadzu, Kyoto, Japan) and a Nicolet iS10 spectrometer (Thermo Fisher Scientific, Madison, WI, USA), respectively. A Waters AutoSpec Premier P776 mass spectrometer (Waters, Milford, MA, USA) or a Shimadzu LCMS-IT-TOF mass spectrometer (Shimadzu, Kyoto, Japan) was used to acquire the high-resolution mass spectra. ECD spectra were recorded on an Applied Photophysics Chirascan apparatus (Applied Photophysics, Surrey, UK). NMR spectra were obtained by using DRX-500, Avance III-600, and Ascend™ 800 MHz spectrometers (Bruker, Karlsruhe, Germany). TLC detection was run on silica gel plates (60 F254). Silica gel (200–300 mesh, Qingdao Makall group Co. Ltd., Qingdao, China) and Sephadex LH-20 (GE Healthcare Bio-Sciences AB, Uppsala, Sweden) were used for column chromatography. A Dr-Flash II apparatus was applied to accomplish the MPLC separations. HPLC purifications were conducted on a Shimadzu LC-CBM-20 system (Shimadzu, Kyoto, Japan), equipped with an Agilent Eclipse XDB-C18 column (5 μm, 9.4 × 250 mm).
+ Open protocol
+ Expand
8

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured with a JASCO P-1020 polarimeter. UV spectra were recorded with a Shimadzu UV-2401A spectrophotometer. IR spectra were recorded on Bruker Tensor 27 spectrometer with a KBr disk. 1D and 2D NMR spectra were recorded on a Bruker Avance III 600 spectrometer. Chemical shifts were reported using TMS as the internal standard. ESI–MS were recorded on Shimadzu UPLC-IT-TOF-MS instrument and HREIMS spectra were measured with a Waters AutoSpec Premier P776 mass spectrometer. Column chromatography (CC) was performed on silica gel (90–200 µm; Qingdao Haiyang Chemical Co. Ltd., Qingdao, China), and MPLC was performed on a Lisui EZ Purify III System packed with RP-18 silica gel (40–63 μm, Merck, 71 Darmstadt, Germany) columns. Precoated silica gel GF254 plates (Qingdao Haiyang Chemical Co. Ltd.) were used for thin-layer chromatography (TLC). Preparative and semipreparative HPLC was performed on Shimadzu LC-8A equipped with a Shimadzu PRC-ODS (K) column and Agilent 1100 apparatus equipped with a Zorbax SB-C-18 75 (Agilent, 9.4 mm × 25 cm) column, respectively. Fractions were monitored by TLC and spots were visualized by Dragendorff’s reagent.
+ Open protocol
+ Expand
9

Structural Elucidation of Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured with a HORIBA SEPA-300 high-sensitive polarimeter. IR spectra were determined on a Bruker Tensor-27 infrared spectrophotometer with KBr disks. UV spectra were recorded on a Shimadzu UV2401A ultraviolet–visible spectrophotometer. HRTOFMS analysis was carried out on an API QSTAR time-of-flight spectrometer and on a Waters Auto Spec Premier P776 mass spectrometer. NMR spectra were recorded on Bruker AV400, DRX-500 and DRX-600 spectrometers at 25 °C, using TMS as an internal standard. Chemical shifts were reported in units of δ (ppm) and coupling constants (J) were expressed in Hz. Column chromatography (CC) were carried out over silica gel (200–300 mesh, Qingdao Haiyang Chemical Co. Ltd), Rp-18 (40–63 μm, Merck), and Sephadex LH-20. Pre-coated silica gel plates (Qingdao Haiyang Chemical Co. Ltd.) were used for TLC. Detection was done under UV light (254 and 365 nm) and by spraying the plates with 10 % sulfuric acid followed by heating. An Agilent series 1100 (Agilent Technologies) were used for HPLC. An Agilent ZORBAX SB-C18 column 5 μm 143 Å column (250 × 9.4 mm) were used for semi-preparative HPLC separations.
+ Open protocol
+ Expand
10

Phytochemical Analysis of Natural Product

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were obtained with a Jasco P-1020 polarimeter. UV spectra were measured on Shimadzu UV-2401A spectraphotometer. IR spectra were detected on a Bruker Tensor-27 infrared spectrophotometer with KBr pellets. 1D and 2D NMR spectra were recorded on Bruker AV-400, and Avance III-600 MHz spectrometers with TMS as the internal standard. Chemical shifts (δ) were expressed in ppm with reference to the solvent signals. HRESIMS analysis and HREIMS were determined on API QSTAR time-of-flight spectrometer and on Waters Auto spec Premier P776 mass spectrometer. Semi-preparative HPLC was performed on an Agilent 1100 liquid chromatography with a Zorbax SB-C18 (9.4 mm × 25 cm) column. Column chromatography was performed on Sephadex LH-20 (GE Healthcare), Silica gel (100–200 and 200–300 mesh, Qingdao Marine Chemical Co., Ltd., Qingdao, China), and Amphichroic RP-18 gel (40–63 μm, Merck, Darmstadt, Germany) and MCI gel (75–150 μm, Mitsubishi Chemical Corporation, Tokyo, Japan). Fractions were monitored by TLC and spots were visualized by heating silica gel plates sprayed with 10 % H2SO4 in EtOH.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!