The largest database of trusted experimental protocols

1250 infinity system

Manufactured by Agilent Technologies
Sourced in United States

The 1250 Infinity system is a liquid chromatography instrument designed for analytical and preparative applications. It offers precise flow control, reliable solvent delivery, and advanced detection capabilities to support a wide range of analytical techniques.

Automatically generated - may contain errors

4 protocols using 1250 infinity system

1

Size-Exclusion Chromatography of WSFs

Check if the same lab product or an alternative is used in the 5 most similar protocols
The WSFs (3 mg/mL) from different ripening points were analyzed by high-performance size-exclusion chromatography coupled with a refractive index detector (HPSEC-RID) using a 1250 Infinity system (Agilent, Santa Clara, CA, USA). The system was equipped with four PL aquagel-OH columns (60, 50, 40 and 30; 429 300 × 7.5 mm) connected in series. The eluent used was 0.2 M NaNO3/0.02% NaN3 (0.6 mL/min). The RID temperature was set at 30 °C20 (link). Average molecular weight (Mw) was calculated using a standard curve of dextrans (Mw 5–1,800 kDa; Sigma-Aldrich (St. Louis, MO, USA)). The void volume (Vo) was the elution time of the heavier molecule (blue dextran; ~1,800 kDa), and the included volume (Vi) was the elution time of glucose.
+ Open protocol
+ Expand
2

Size Exclusion Chromatography of MCP

Check if the same lab product or an alternative is used in the 5 most similar protocols
MCP and MCP fractions were analyzed by high performance size exclusion chromatography coupled to a refractive index detector (HPSEC-RID) using a 1250 Infinity system (Agilent, Santa Clara, CA) equipped with four PL-aquagel-OH columns (60, 50, 40 and 30; 300 × 7.5 mm; Agilent) connected in tandem. The eluent was 0.2 M NaN03/0.02% NaN3 (0.6 mL/min) and the RID temperature was set at 30 °C. Dextran equivalent average molecular size was calculated using a standard curve of dextrans (MW 5–1800 kDa). The void volume (Vo) was the elution time of the heavier molecule (blue dextran; ~1800 kDa), and the elution volume (Ve) was the release time of lighter molecule (glucose).
+ Open protocol
+ Expand
3

Papaya WSF Molecular Mass Distribution

Check if the same lab product or an alternative is used in the 5 most similar protocols
Molecular mass distribution of the papaya WSF was analyzed by high performance size exclusion chromatography coupled to a refractive index detector (HPSEC-RID) using a 1250 Infinity system (Agilent, Santa Clara, CA). Samples were diluted with water (1 mg/mL), injected (25 µL) and separation was conducted through four PL aquagel-OH MIXED-M (300 × 7.5 mm, 8 μm) columns in tandem (Agilent, Santa Clara, CA). The eluent was 0.2 M NaNO3 at 35 °C with a flow of 0.6 mL·min−1. Molecular weights were estimated using dextran T-series (5, 25, 50, 80, 150 and 410 kDa; FlukaTM) as external standards.
+ Open protocol
+ Expand
4

Papaya Polysaccharide Molecular Mass Distribution

Check if the same lab product or an alternative is used in the 5 most similar protocols
Molecular mass distribution of the papaya polysaccharides was analyzed by HPSEC-RID via a 1250 Infinity system (Agilent, Santa Clara, CA, USA). Samples were diluted with water (0.5 mg/mL), injected (25 μL) and separation was conducted through two PL aquagel-OH MIXED-M (300 mm × 7.5 mm, 8 μm) columns (Agilent). The eluent was 0.2 M NaNO3 at 35°C with a flow of 0.6 mL/min. Molecular weights were estimated using dextran T-series (5, 12, 25, 50, 80, 150, 410, and 750 kDa) (Sigma; St. Louis, MO, USA) as external standards.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!