The largest database of trusted experimental protocols

Minolta chroma meter cr 210

Manufactured by Konica Minolta
Sourced in Japan

The Minolta Chroma Meter CR-210 is a portable color measurement instrument. It is designed to measure and display color values precisely.

Automatically generated - may contain errors

24 protocols using minolta chroma meter cr 210

1

Colorimetric Analysis of Reduced-Salt Batters

Check if the same lab product or an alternative is used in the 5 most similar protocols
The color of each reduced-salt batters and frankfurters was determined using a colorimeter (Minolta Chroma meter CR-210, Minolta Ltd., Japan; illuminate C, calibrated with a white plate, L*=+97.83, a*=−0.43, b*=+1.98). Six measurements for each of five replicates were taken. Lightness (CIE L*), redness (CIE a*), and yellowness (CIE b*) values were recorded.
+ Open protocol
+ Expand
2

Colorimetric Analysis of Pork Mixtures

Check if the same lab product or an alternative is used in the 5 most similar protocols
The color of each pork mixture preparation was determined using a colorimeter (Minolta Chroma meter CR-210, Japan; illuminate C, standard with a white plate, Commission Internationale de l’Eclairage (CIE) L* = +97.83, CIE a* = −0.43, CIE b* = +1.98) in triplicate. Lightness (CIE L*-value), redness (CIE a*-value), and yellowness (CIE b*-value) values were obtained.
+ Open protocol
+ Expand
3

Colorimetric Analysis of Cooked Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The color measurements of samples were conducted after cooking. The color values of core sections from each cooked sample were measured using a colorimeter (Minolta Chroma meter CR-210, Konica Minolta, Tokyo, Japan) with a CIE L* (lightness), CIE a* (redness), and CIE b* (yellowness). Before color measurement, the colorimeter was calibrated with a white plate (CIE L* = +97.83, CIE a* = −0.43, CIE b* = +1.98). Ten readings were obtained for each sample.
+ Open protocol
+ Expand
4

Color Measurement of Material Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The color of each sample was determined using a colorimeter (Minolta Chroma meter CR-210, Minolta Ltd., Osaka, Japan; illuminate C, calibrated with a white plate, L*=+97.83, a*=−0.43, b*=+1.98) from cross-sections selected from five random locations on cross-section of each sample. Lightness (CIE L*- value), redness (CIE a*- value), and yellowness (CIE b*- value) values were recorded.
+ Open protocol
+ Expand
5

Color Characterization with Colorimeter

Check if the same lab product or an alternative is used in the 5 most similar protocols
The color of each sample was determined using a colorimeter (Minolta Chroma meter
CR-210; Minolta, Ltd., Japan; illuminate C, calibrated with a white plate,
L*=+97.83, a*=–0.43, b*=+1.98). The CIE L* (lightness), a* (redness), and
b* (yellowness) values were recorded.
+ Open protocol
+ Expand
6

Characterization of Glasswort Powder

Check if the same lab product or an alternative is used in the 5 most similar protocols
Freeze-dried red and green glasswort powder, which was prepared with all parts of the glasswort including the root, stem and leaf, was purchased from a local market. Green glasswort was harvested in Sinan in August 2013, and red glasswort was harvested at the same farm in November 2013. The pH value, instrumental color, mineral composition, and total dietary fiber content of the freeze-dried red and green glasswort powder are shown in Table 1. The pH values of freeze-dried glasswort powder was determined using a pH meter (Model 340, Mettler-Toledo GmbH, Switzerland), and the instrumental color was determined using a colorimeter (Minolta Chroma meter CR-210, Japan). Major mineral elements (Na, K, Ca, and Mg) were analyzed with atomic absorption spectrophotometry method (Optima 30000 XL, Perkin Elmer) described by Rupérez (2002) (link), the total dietary fiber content was determined with the modified AOAC enzymaticgravimetric method (AOAC, 1995 ), as described by Choi et al. (2009) (link).
+ Open protocol
+ Expand
7

Color Analysis of Duck Meat Jellies

Check if the same lab product or an alternative is used in the 5 most similar protocols
Instrumental color of duck meat jellies were determined using a colorimeter (Minolta Chroma meter CR-210, Japan; calibrated with a white plate, CIE L*=+97.83, CIE a*=−0.43, CIE b*=+1.98), equipped with a 50 mm aperture. The setting for the illuminant was C illuminant source and the observer was standard 2°. One measurement on surface of each meat jelly was taken, and total six measurements were obtained from six locations of each sample. CIE L* (lightness), CIE a* (redness), and CIE b* (yellowness) values were recorded.
+ Open protocol
+ Expand
8

Colorimetric Analysis of Chicken Patties

Check if the same lab product or an alternative is used in the 5 most similar protocols
The color of each raw and cooked chicken patty was determined using a colorimeter (Minolta Chroma meter CR-210, Minolta Co., Japan; illuminate C, calibrated with a white plate, L*=+97.83, a*=−0.43, b*=+1.98). The lightness (CIE L*-value), redness (a*-value), and yellowness (b*-value) values were recorded.
+ Open protocol
+ Expand
9

Colorimetric Analysis of Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The color of each sample was determined using a colorimeter (Minolta Chroma meter CR-210, Minolta Ltd., Japan; illuminate C, calibrated with a white plate, L*=+97.83, a*=−0.43, b*=+1.98). CIE L*-value (lightness), CIE a*-value (redness), and CIE b*-value (yellowness) values were recorded.
+ Open protocol
+ Expand
10

Meat Color Evaluation over Storage Time

Check if the same lab product or an alternative is used in the 5 most similar protocols
Meat color was evaluated with a colorimeter (Minolta Chroma Meter CR-210; Konica Minolta Inc., Tokyo, Japan), calibrated against a white plate (CIE L* = +97.83; CIE a* = −0.43; CIE b* = +1.98). CIE L* (lightness), CIE a* (redness), and CIE b* (yellowness) were measured for the surfaces of samples stored for 0 days, 7 days, 14 days, 21 days, and 28 days.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!