The largest database of trusted experimental protocols

Fl 600 fluorescence absorbance plate reader

Manufactured by Agilent Technologies
Sourced in United States

The FL-600 Fluorescence/Absorbance Plate Reader is a versatile instrument designed for fluorescence and absorbance measurements. It can perform various types of assays, including cell-based, biochemical, and molecular biology assays, in a high-throughput microplate format.

Automatically generated - may contain errors

2 protocols using fl 600 fluorescence absorbance plate reader

1

Optimization of Inclusion Body Solubility

Check if the same lab product or an alternative is used in the 5 most similar protocols
IBs were suspended in 50 mM Tris-HCl buffer, pH 8.0, containing SDS from 0.01 to 0.1% or urea from 1 to 8 M, and incubated for a specified time (from 5 min to 24 h). Turbidity of the samples was measured at 350 nm with a μQuant spectrophotometer (BioTEK Instruments, Inc., USA). Fluorescence intensity of the PldA-GFP IBs solutions in urea and SDS was recorded with a FL-600 Fluorescence/Absorbance Plate Reader (BioTEK Instruments, USA) with excitation wavelength at 495 nm and emission at 530 nm. The experiments were performed in three biological replicates. Results show the mean ± standard deviation (SD).
+ Open protocol
+ Expand
2

Caspase3 Activity Assay Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Equimolar amounts of Grb7-6xHis (0.30 µg, 0.05µM), Grb7-RAPH-6xHis (0.14 µg, 0.05µM) and Hax1-6xHis (0.16 µg, 0.05µM) proteins were separately incubated with Caspase3-6xHis (0.03µg, 0.005µM) and Ac-DEVD-AMC (0.50µg, 7.4µM) in Caspase assay buffer (50mM HEPES, 100mM NaCl, 0.1% w/v CHAPS, 10mM DTT, 1mM EDTA, 10% w/v Glycerol, pH 7.4; total volume: 100µL) in one well of 96-well plate. Each reaction was repeated in triplicate using 3 wells of a 96-well plate. The plate was then immediately placed into a Bio-Tek FL600 fluorescence/absorbance plate reader and the fluorescence (Ex360nm/Em460nm) from liberated AMC was recorded every 1 to 2 minutes for 40 minutes using Bio-Tek KC4 v3.4 software.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!