The largest database of trusted experimental protocols

5 protocols using purelab purification system

1

Lipid Extraction and Standards

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following chemicals were purchased from Fisher Scientific (Ottawa, ON, Canada): LC-grade chloroform, methanol, acetonitrile, formic acid, acetic acid and ammonium acetate. For solutions preparation, deionized water (PURELAB Purification System, ELGA Labwater, ON, Canada) was employed. Phospholipids, sphingolipids and glycolipids standards were used (Avanti Polar Lipids Inc., Alabaster, AL, USA).
+ Open protocol
+ Expand
2

Quantification of Isotopically Labeled Thyroid Hormone

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acetonitrile (Ultra Chromasolv, LCMS grade), triethylammonium bicarbonate (TEAB) buffer (1 M), ethylenediamine-tetraacetic acid (EDTA, anhydrous), HSA (lyophilized powder, 97–99%), and porcine trypsin were from Sigma-Aldrich (St. Louis, MO). Methanol (Optima, LCMS grade), formic acid (Optima, LCMS grade), and iodoacetamide (IAA) were from Fisher Scientific (Pittsburgh, PA). Purified human Hb was purchased from MP Biomedicals, LLC (Santa Ana, CA). Isotopically labeled T3 (iT3) with sequence AL-[15N,13C-Val]-LIAFAQYLQQCPFEDH-[15N,13C-Val]-K was custom-made (>95%, BioMer Technology, Pleasanton, CA), and the carbamidomethylated iT3 (IAA-iT3)[18 (link)] was used as an internal standard to monitor retention time and mass drifts. Water was prepared with a PureLab purification system (18.2 mΩ cm resistivity at 25 °C; Elga LabWater, Woodridge, IL).
+ Open protocol
+ Expand
3

Comprehensive Lipid Standard Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC grade acetonitrile, chloroform and methanol were purchased from Fisher Scientific, Canada; deionized water was obtained from PURELAB Purification System (ELGA Labwater, ON, Canada). HPLC grade acetic acid, formic acid, ammonium formate and ammonium acetate were purchased from Sigma-Aldrich (ON, Canada). Each lipid class was purchased as individual from Avanti Polar Lipids (Alabaster, AL, USA) and used to make a complex lipid standard mixture consisting SQDG 16:0/16:0, MGDG 16:3(7Z,10Z,13Z)/18:3(9Z,12Z,15Z), PA 18:1(9Z)/18:1(9Z), PG 18:0/20:4(5Z,8Z,11Z,14Z), PC 18:0/20:4(5Z,8Z,11Z,14Z), PE 18:0/20:4(5Z,8Z,11Z,14Z), diether PC O-18:0/O-18:0, plasmalogen PC P-18:0/20:4(5Z,8Z,11Z,14Z), plasmalogen PE P-18:0/20:4(5Z,8Z,11Z,14Z), MMPE 16:0/16:0 and DMPE 16:0/16:0, LPA 20:4(5Z,8Z,11Z,14Z), LPC 18:1(9Z), LPE 18:0, plasmalogen LPE P-18:0; PI 18:0/20:4(5Z,8Z,11Z,14Z); DLCL 18:2(9Z,12Z)/18:2(9Z,12Z), and SM d18:1/18:0. Aliquots of the prepared standard mixture were used for method development.
+ Open protocol
+ Expand
4

Hemoglobin Quantification Using Labeled T3

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acetonitrile (Ultra Chromasolv, LCMS grade), triethylammonium bicarbonate (TEAB) buffer (1 M), ethylenediamine-tetraacetic acid (EDTA, anhydrous), and porcine trypsin were from Sigma-Aldrich (St. Louis, MO). Methanol (Optima, LCMS grade), formic acid (Optima, LCMS grade), and iodoacetamide (IAA) were from Fisher Scientific (Pittsburgh, PA). Purified human hemoglobin was from MP Biomedicals, LLC (Santa Ana, CA). Isotopically labeled T3 (iT3) with sequence AL-[15N,13C-Val]-LIAFAQYLQQCPFEDH-[15N,13C-Val]-K was custom-made (>95%, BioMer Technology, Pleasanton, CA), and the carbamidomethylated iT3 (IAA-iT3)[14 (link)] was used as an internal standard to monitor retention time and mass drifts, as well as drift in instrument performance. Water was prepared with a PureLab purification system (18.2 mΩ cm resistivity at 25 °C; Elga LabWater, Woodridge, IL).
+ Open protocol
+ Expand
5

Proteomics Workflow for T3 Peptide Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Triethylammonium bicarbonate buffer (TEAB), ethylenediamine-tetraacetic acid (EDTA, anhydrous), ammonium sulfate, porcine trypsin, HSA (lyophilized powder, 97–99%), acetonitrile (Ultra CHROMASOLV®, LC-MS grade), acetic acid (LCMS grade), L-glutathione (reduced), L-cysteine, L-homocysteine, iodine, iodoacetamide (IAA), ammonium sulfate, dimethyl sulfoxide (DMSO), hydrogen peroxide (30% aqueous solution) were from Sigma-Aldrich (St. Louis, MO). Methanol (Optima®, LCMS grade), tris(2-carboxyethyl)phosphine (TCEP), formic acid (Optima®, LCMS Grade), were from Fisher Scientific (Pittsburgh, PA). Purified water (18.2 mΩ cm resistivity at 25°C) was prepared with a PureLab purification system (Elga LabWater, Woodridge, IL). The following chemicals were custom synthesized: T3 peptide with sequence ALVLIAFAQYLQQCPFEDHVK (>97%, Biomatik, Wilmington, DE), isotopically modified T3 with sequence AL-[15N, 13C-Val]-LIAFAQYLQQCPFEDH-[15N, 13C-Val]-K (>95%, BioMer Technology, Pleasanton, CA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.