The largest database of trusted experimental protocols

2 protocols using p 2300

1

Spectroscopic Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were measured on a Yanagimoto micro apparatus without correction. Measurement of optical rotation was carried out on a JASCO P-2300 in CHCl3 solution at 23 °C. IR spectra were recorded using a Perkin-Elmer Model Spectrum 100. 1H (400 or 600 MHz)- and 13C (100 or 150 MHz)-NMR spectra were recorded on a JEOL AL-400 or ECA-600 spectrometer using tetramethylsilane as an internal standard. The chemical shifts are expressed on the δ scale. EI-MS and HREI-MS were measured at 30–60 eV (direct inlet) with a JEOL Model JMS-700 and the relative intensities of peaks are reported with reference to the most intense peak higher than m/z 100. TLC was carried out on pre-coated silica gel 60 (Merck 5554) with n-hexane-EtOAc or CHCl3-MeOH as the developing phase. Detection was carried out by spraying with concentrated H2SO4 followed by heating. HPLC was performed on a Hitachi L-6000 equipped with a Hitachi L-7490 RI detector. The following column and solvents were used for elution: Mightysil, RP-18 GP 250–10 (25 cm x 10 mm i.d., 5μm) with MeOH-H2O or CH3CN-H2O.
+ Open protocol
+ Expand
2

Characterization Methods for Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
General Experimental Procedures EI-MS and FAB-MS were measured on a JMS-MS 700 mass spectrometer (JEOL, Tokyo, Japan). 1 (link) H-and 13 C-NMR spectra were recorded on a JNM-AL-400 NMR spectrometer (JEOL) at 400 MHz for 1 H and 100 MHz for 13 (link) C in CDCl 3 (δ H 7.24, δ C 77.0). Specific rotations were obtained with the digital polarimeter P-2300 (JASCO, Tokyo, Japan). UV spectra were measured on the UV-visible (Vis) spectrophotometer U-3310 (Hitachi High Technologies Co., Ltd., Tokyo, Japan). ECD spectra were measured with a JASCO J-720 spectropolarimeter. IR spectra were recorded on the Fourier transform infrared spectrometer FT-710 (Horiba Ltd., Kyoto, Japan). Preparative HPLC was performed using an L-6200 HPLC system (Hitachi High Technologies Co., Ltd.).
Materials PTP1B was purchased from Enzo Life Sciences (Farmingdale, NY, U.S.A.). p-Nitrophenyl phosphate (pNPP) was purchased from Sigma-Aldrich (St. Louis, MO, U.S.A.). Oleanolic acid was purchased from Tokyo Chemical Industry (Tokyo, Japan). Plastic plates (96-well) were purchased from Corning Inc. (Corning, NY, U.S.A.). All other chemicals including organic solvents were purchased from Wako Pure Chemical Industries, Ltd. (Osaka, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!