Formvar supporting membranes

Manufactured by Merck Group
Sourced in Germany

Formvar supporting membranes are thin, transparent films used as a support structure for specimens in electron microscopy. They provide a stable platform for the sample, allowing for high-resolution imaging and analysis.

Automatically generated - may contain errors

2 protocols using formvar supporting membranes

1

Tissue Preparation for Transmission Electron Microscopy

Check if the same lab product or an alternative is used in the 5 most similar protocols
After 3 rinses in 0.15-M sodium phosphate buffer (pH 7.2), the tissue samples were postfixed in 1% OsO4 in 0.15-M sodium phosphate buffer (pH 7.2) for 2 h. Following dehydration in a graded series of ethanol, the specimens were transferred to propylene oxide and embedded in Epon (TAAB Laboratories Equipment Ltd., Aldermaston, UK). Ultrathin sections were cut with a Reichert-Jung Ultracut E microtome (Leica Microsystems), collected on 1-hole copper grids with formvar supporting membranes (Merck, Darmstadt, Germany) and stained with uranyl acetate and lead citrate. A Philips CM 100 transmission electron microscope (Philips, Amsterdam, the Netherlands) was used to view the sections, and digital images were obtained with an Olympus Soft Imaging Solutions (OSIS) Veleta side-mounted CCD camera (Olympus, Tokyo, Japan).
+ Open protocol
+ Expand
2

Transmission Electron Microscopy Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
Following 3 rinses in 0.15 M sodium phosphate buffer (pH 7.2), the specimens were postfixed in 1% OsO4 in 0.15 M sodium phosphate buffer (pH 7.2) for 2 h. After dehydration in a graded series of ethanol, the samples were transferred to propylene oxide and embedded in Epon (TAAB Laboratories Equipment Ltd., Aldermaston, UK). Ultrathin sections were cut with a Reichert-Jung Ultracut E microtome (Leica Microsystems), collected on 1-hole copper grids with formvar supporting membranes (Merck, Darmstadt, Germany) and stained with uranyl acetate and lead citrate. A Philips CM 100 transmission electron microscope (Philips, Amsterdam, The Netherlands) was used to view the sections, and digital images were obtained with an Olympus Soft Imaging Solutions (OSIS) Veleta side-mounted CCD camera (Olympus, Tokyo, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!