Isolera one purification system

Manufactured by Biotage

The Isolera One purification system is a compact, automated flash chromatography system designed for efficient and reliable separation and purification of chemical compounds. It utilizes a high-performance solvent delivery system and integrated UV/VIS detector to facilitate the isolation and recovery of target analytes from complex mixtures.

Automatically generated - may contain errors

4 protocols using isolera one purification system

1

Comprehensive Analytical Techniques for Chemical Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were recorded using a JEOL JNM-ECZ400 spectrometer at 400 MHz for 1H NMR and 100 MHz for 13C NMR. Mass spectra (MS) were obtained using JEOL JMS-T100LP AccuTOF LC-plus 4 G (ESI).
Preparative HPLC was performed on an Inertsil ODS-3 (10.0 × 250 mm) column (GL Sciences Inc.) using an HPLC system composed of a pump (PU-2080, JASCO) and a detector (MD-2015). Preparative MPLC was performed on an Isolera One purification system (Biotage) equipped with a Biotage SNAP Ultra C18 column (for reverse phase separation) or on an MPLC system comprising a pump and detector (EPCLC AI-580S, Yamazen) and equipped with a silica gel column (silica gel 40 μm or Amino 40 μm, Yamazen) (for normal phase separation). LC-MS analysis was performed on an Acquity UPLC H-Class system (Waters) equipped with an Acquity UPLC BEH C18 1.7 μm (2.1 × 50 mm) column (Waters) and an MS detector (QDa or Xevo TQD, Waters).
+ Open protocol
+ Expand
2

Chiral Compound Purification and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemicals and reagents were purchased from commercial sources and used without further purification. The proton NMR spectrum was recorded on a Bruker 400 MHz (100 MHz) spectrometer equipped with a cryogenic probe. Proton chemical shifts are reported in ppm (δ) relative to tetramethylsilane and calibrated using the residual solvent resonance (DMSO, δ 2.50 ppm). The NMR spectrum was recorded at ambient temperature (about 25°C). Preparative reversed-phase chromatography was performed on a Biotage Isolera One purification system, using C-18 silica as the stationary phase, with CH3OH as the strong solvent and H2O (0.1% HCl by weight) as the weak solvent. Liquid chromatography/mass spectrometry (LCMS) was performed on an Agilent 1290 UPLC-LCMS equipped with a C-18 silica column (1.8 μm, 2.1 × 50 mm) using CH3CN/H2O (0.1% acetic acid by volume): 5% to 95% CH3CN over 4 min; 1 mL/min. The optical purity of the products was determined by derivatization with N-(5-fluoro-2,4-dinitrophenyl)alanamide (FDNP-alanamide)20 as described below.
+ Open protocol
+ Expand
3

Analytical Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Nuclear magnetic resonance (NMR) spectra were recorded on a JEOL JNM-LA400 at 400 MHz for 1H NMR and at 100 MHz for 13C NMR. Mass spectra (MS) were measured on a JEOL JMS-T100LP AccuTOF LC-plus 4G (electrospray ionization). Preparative high-performance liquid chromatography (HPLC) was performed on an Inertsil ODS-3 (10.0 × 250 mm) column (GL Sciences Inc.) using an HPLC system composed of a pump (PU-2080, JASCO) and a detector (MD-2015). Preparative medium pressure liquid chromatography (MPLC) was performed on an Isolera One purification system (Biotage) equipped with a Biotage SNAP Ultra C18 column (for reverse phase separation) or on an MPLC system composed of a pump and a detector (EPCLC-AI-580S, Yamazen) and equipped with a silica gel column (silica gel 40 μm or Amino 40 μm, Yamazen) (for normal phase separation). Liquid chromatography–mass spectrometry analysis was performed on an Acquity UPLC H-Class System (Waters) equipped with an Acquity UPLC BEH C18 1.7 μm (2.1 × 50 mm) column (Waters) and an MS detector (QDa, Waters).
+ Open protocol
+ Expand
4

NMR, MS, and HPLC/MPLC Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were recorded using a JEOL JNM-LA400 spectrometer at 400 MHz for 1H NMR and 100 MHz for 13C NMR. Mass spectra (MS) were obtained using JEOL JMS-T100LP AccuTOF LC-plus 4G (ESI).
Preparative HPLC was performed on an Inertsil ODS-3 (10.0 × 250 mm) column (GL Sciences Inc.) using an HPLC system composed of a pump (PU-2080, JASCO) and a detector (MD-2015). Preparative MPLC was performed on an Isolera One purification system (Biotage) equipped with a Biotage SNAP Ultra C18 column (for reverse phase separation) or on an MPLC system comprising a pump and detector (EPCLC AI-580S, Yamazen) and equipped with a silica gel column (silica gel 40 μm or Amino 40 μm, Yamazen) (for normal phase separation). LC-MS analysis was performed on an Acquity UPLC H-Class system (Waters) equipped with an Acquity UPLC BEH C18 1.7 μm (2.1 × 50 mm) column (Waters) and an MS detector (QDa or Xevo TQD, Waters).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!