The largest database of trusted experimental protocols

Metamorph 4 5 4

Manufactured by Universal Imaging

MetaMorph 4.5/4.6 is a software application developed for image acquisition, processing, and analysis. It provides a range of tools for managing and manipulating digital images obtained from microscopy and other imaging systems.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using metamorph 4 5 4

1

Mesenteric ROS Visualization in Shock

Check if the same lab product or an alternative is used in the 5 most similar protocols
The rats were divided into the following groups: sham-control (n=5), HS (n=5) and Bcl-xL plus HS (n=5). HS was induced as described above. Visualization and quantification of ROS from the mesenteric post-capillary venules was performed using dihydrorhodamine 123 (DHR 123; 50 mg/kg) using intravital microscopy. Images of the mesenteric venules were obtained before the shock period and at 10, 20, 30, 40, 50 and 60 min into resuscitation. To determine relative expression of ROS, the fluorescent intensity was measured in two areas along the vessel using MetaMorph 4.5/4.6 (Universal Imaging Corp.). Values of DHR 123 fluorescence were expressed as change in intensity over time versus baseline values.
+ Open protocol
+ Expand
2

Visualization of Oxidative Stress in Shock

Check if the same lab product or an alternative is used in the 5 most similar protocols
The rats were divided into the following groups: sham-control (n=5), hemorrhagic shock (n=5), and Bcl-xL plus hemorrhagic shock (n=5). Hemorrhagic shock was induced as described above. Visualization and quantification of ROS from the mesenteric post capillary venules was performed using dihydrorhodamine 123 (DHR 123) (50 mg/kg) by intravital microscopy. Images of the mesenteric venules were obtained prior to the shock period and at 10, 20, 30, 40, 50 and 60 minutes into resuscitation. To determine relative expression of ROS, the fluorescent intensity was measured in two areas along the vessel using MetaMorph 4.5/4.6 (Universal Imaging Corp., Downingtown, PA). Values of DHR 123 fluorescence were expressed as change in intensity over time versus baseline values.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!