The largest database of trusted experimental protocols

20 protocols using infinity alt kit

1

Biochemical Profiling of Liver Function

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of ALT were determined using Infinity ALT kit (Thermo Scientific). Hepatic triglyceride levels were measured using Triglyceride Liquid Reagents kit (Pointe Scientific). Levels of serum LPS and fecal albumin were determined by ELISA kits (Lifeome Biolabs and Bethyl Labs, respectively). Serum levels of ethanol were measured using Ethanol Assay kit (BioVision).
+ Open protocol
+ Expand
2

Biochemical Profiling of Liver Function

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of ALT were determined using Infinity ALT kit (Thermo Scientific). Hepatic triglyceride levels were measured using Triglyceride Liquid Reagents kit (Pointe Scientific). Levels of serum LPS and fecal albumin were determined by ELISA kits (Lifeome Biolabs and Bethyl Labs, respectively). Serum levels of ethanol were measured using Ethanol Assay kit (BioVision).
+ Open protocol
+ Expand
3

Biochemical Markers of Hepatic Injury

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of ALT were determined using Infinity ALT kit (Thermo Scientific). Hepatic triglyceride levels were measured using Triglyceride Liquid Reagents kit (Pointe Scientific). Serum levels of ethanol were measured using Ethanol Assay kit (BioVision). Serum levels of cytokines were measured using Proinflammatory Panel 1 (mouse) kit (Meso Scale Diagnostics). All results were measured using the software SoftMax Pro 7.0.3.
+ Open protocol
+ Expand
4

Evaluating Liver and Intestinal Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of ALT were measured using the Infinity ALT kit (Thermo Scientific). Hepatic triglyceride levels were measured using the Triglyceride Liquid Reagents Kit (Pointe Scientific). Serum levels of ethanol were measured using the Ethanol Assay Kit (BioVision). Serum levels of intestinal fatty-acid binding protein (IFABP) were measured using the iFABP ELISA kit (MyBioSource). Serum levels of zonulin were measured using the Human Zonulin ELISA Kit (MyBioSource)17 .
+ Open protocol
+ Expand
5

Quantifying Liver and Bile Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
Levels of plasma ALT were measured using the Infinity ALT kit (Thermo Scientific, Waltham, MA). Plasma and hepatic triglyceride and cholesterol levels were measured using the Triglyceride Liquid Reagents Kit (Pointe Scientific, Canton, MI) and Cholesterol Liquid Reagents kit (Pointe Scientific), respectively. Plasma levels of leptin were measured using the mouse leptin enzyme-linked immunosorbent assay kit according to the manufacturer’s protocol (Crystal Chem, Elk Grove Village, IL). Total bile acids and the bile acid pool were quantified using a Mouse Total Bile Acid Kit (Crystal Chem) as described.59 (link) For the total bile acid pool, total liver bile acids, total gallbladder bile acids, and total bile acids from the small intestine and cecum, contents were measured and calculated per gram of body weight.
+ Open protocol
+ Expand
6

Comprehensive Metabolic Assessment in Mouse Models

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels of ethanol were measured using the Ethanol Assay Kit (BioVision). Levels of ALT were measured using Infinity ALT kit (Thermo Scientific). Hepatic triglyceride levels were measured using the Triglyceride Liquid Reagents Kit (Pointe Scientific). Hepatic alcohol dehydrogenase (ADH) activity was measured using the ADH Assay Kit (BioVision). Plasma LPS (Cloud-Clone Corp), and fecal albumin levels (Bethyl lab) were measured by ELISA. Whole blood was collected into potassium EDTA–containing Microvette 100 tubes (Sarstedt), and automated complete blood counts (CBCs) were obtained using a Scil Vet abc automatic hematology analyzer (Scil Animal Care). For insulin tolerance test (ITT), following a 6-hour fasting period, an intraperitoneal dose of 0.35 or 1 U kg−1 insulin (novolin, Novo Nordisk Inc.) was administered to mice on RC diet or HFD, respectively, and blood glucose was measured at indicated time points. Plasma and liver levels of iron were measured using a kit from Thermo Scientific.
+ Open protocol
+ Expand
7

Serum Liver Enzyme Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Venous blood of mice was taken from the tail vein at different time points after APAP treatment. Serum ALT and AST levels were measured using the Infinity ALT Kit (Thermo Scientific) and AST Kit (Bioo Scientific), respectively. Briefly, 10-μL serum was added into 100-μL ALT or AST reagent, followed by reading of 340 nm at 37°C using a Wallac Victor 1420 Multilabel Counter microplate reader (PerkinElmer). Each sample was measured in triplicate.
+ Open protocol
+ Expand
8

Plasma Biomarker Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Levels of plasma alanine amino-transferase (ALT) were measured using infinity ALT kit (Thermo Fisher Scientific, Waltham, MA). Triglyceride levels were measured using the Triglyceride Liquid Reagents Kit (Pointe Scientific, Canton, MI). Levels of plasma ethanol were measured using the Ethanol Assay Kit (Bio Vision, Milpitas, CA).
+ Open protocol
+ Expand
9

Fecal Albumin and Liver Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fecal albumin levels were measured by ELISA (Mouse Albumin ELISA kit E99-134, BETHYL). The plasma levels of alanine aminotransferase (ALT) and hepatic levels of triglyceride were measured using the Infinity ALT kit (Thermo Fisher Scientific) and Triglyceride Liquid Reagents Set (T7532-120, Pointe Scientific), respectively. Plasma lipopolysaccharide (LPS) levels were measured by ELISA (CEB526Ge; Cloud-Clone Corp.).
+ Open protocol
+ Expand
10

Serum ALT Measurement in DEN-Treated Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Venous blood of mice was collected from the tail vein 0, 24, and 72 h after DEN treatment. Blood was kept at 4 °C for overnight and centrifuged at 200 × g for 20 min to isolate serum. ALT was measured using the Infinity™ ALT kit (Thermo Scientific, Middletown, VA) and is reported as mean ± SD. Briefly, 10 μl of serum was added to 100 μl ALT reagent and measured at 37 °C at 340 nm. Each sample was measured in triplicate and three mice were used in each group.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!